4.9 Service procedure
Maintenance
Every 250 hours service
WA500-6H – VEAM430100
4-55
4.9.7
Every 250 hours service
Maintenance for every 50 and 100 hours service should be car-
ried out at the same time.
Check battery electrolyte level
Carry out this check before operating the machine.
WARNING
z
Do not use the battery if the battery electrolyte level is below
the (MINIMUM) LOWER LEVEL line. This will accelerate
deterioration of the inside of the battery and reduce the ser-
vice life of the battery. In addition, it may also cause an
explosion.
z
The battery generates flammable gas and there is danger of
explosion, so do not bring fire or sparks near the battery.
z
Battery electrolyte is dangerous. If it gets in your eyes or on
your skin, wash it off with a large amount of water and con-
sult a doctor.
z
When adding distilled water to the battery, do not allow the
battery electrolyte to go above the (MAXIMUM) UPPER
LEVEL line. If the electrolyte level is too high, it may leak
and cause damage to the paint surface or corrode other
parts.
NOTE
When adding distilled water in cold weather, add it before start-
ing operations in the morning to prevent the electrolyte from
freezing.
Try to check the electrolyte level on the daily basis. Be sure to
check it at least once a month.
When checking electrolyte level from side of battery
If it is possible to check the electrolyte level from the side of the
battery, check as follows.
1. Use a wet cloth to clean the area around the electrolyte level
lines and check that the electrolyte level is between the
UPPER LEVEL (U.L.) and LOWER LEVEL (L.L.) lines.
If the battery is wiped with a dry cloth, static electricity may
cause a fire or explosion.
If the battery is wiped with a dry cloth, static electricity may
cause a fire or explosion.
GK032268
Upper Level
Lower level
Summary of Contents for WA500-6H
Page 2: ......
Page 3: ...Foreword WA500 6H VEAM430100 1 1 1 Foreword...
Page 26: ...1 7 CE Conforming equipment Foreword 1 24 WA500 6H VEAM430100...
Page 254: ...3 7 Troubleshooting Operation 3 188 WA500 6H VEAM430100...
Page 344: ...4 9 Service procedure Every 12000 hours service Maintenance 4 90 WA500 6H VEAM430100...
Page 345: ...Technical Data WA500 6H VEAM430100 5 1 5 Technical Data...
Page 347: ...Technical Data 5 1 Technical data WA500 6H VEAM430100 5 3 GK032301 A B H I G C E F D...
Page 352: ...5 4 Limit values for slopes Technical Data 5 8 WA500 6H VEAM430100...
Page 401: ...Index WA500 6H VEAM430100 7 1 7 Index...
Page 407: ...Notes WA500 6H VEAM430100 8 1 8 Notes...
Page 408: ...Notes 8 2 WA500 6H VEAM430100...
Page 409: ...Notes WA500 6H VEAM430100 8 3...
Page 410: ...Notes 8 4 WA500 6H VEAM430100...
Page 411: ...Notes WA500 6H VEAM430100 8 5...
Page 412: ...Notes 8 6 WA500 6H VEAM430100...