32. Torque converter lock-up switch
(Option)
WARNING
When traveling down slopes of a grade of more than 6°, never
depress the accelerator pedal fully, regardless of whether the
torque converter lock-up switch is ON or OFF. It is extremely
dangerous to drive too fast.
NOTE
To prevent overrun when the machine next travels at high
speed, do not shift down.
When traveling in F3 at a speed of 17 km/h (10.6 MPH) or more,
do not shift down to F2.
When traveling in F4 at a speed of 30 km/h (18.6 MPH) or more,
do not shift down to F3.
If the transmission is shifted down under the above conditions,
the overrun prevention function is actuated and the speed range
is maintained until the travel speed is reduced to the condition
for shifting gear.
When the actual travel speed range is 2nd - 4th in both forward
and reverse, the torque converter lock-up function is actuated
according to the travel speed and the transmission changes to
direct drive.
Use this switch (32) to operate the torque converter lock-up
function.
Position (a): ON
The pilot lamp inside the switch lights up and the lock-up is actu-
ated according to the travel speed. When the lock-up is in use,
the lock-up pilot lamp on the machine monitor lights up.
Position (b): OFF
Press this to cancel the lock-up.
REMARK
The torque converter lock-up function makes it possible to
improve the efficiency of power transmission when traveling at
high speed and also reduces the fuel consumption.
When traveling downhill and using the braking force of the
engine, actuate the torque converter lock-up.
GK050072
GK050073
a
b
Summary of Contents for WA500-6H
Page 2: ......
Page 3: ...Foreword WA500 6H VEAM430100 1 1 1 Foreword...
Page 26: ...1 7 CE Conforming equipment Foreword 1 24 WA500 6H VEAM430100...
Page 254: ...3 7 Troubleshooting Operation 3 188 WA500 6H VEAM430100...
Page 344: ...4 9 Service procedure Every 12000 hours service Maintenance 4 90 WA500 6H VEAM430100...
Page 345: ...Technical Data WA500 6H VEAM430100 5 1 5 Technical Data...
Page 347: ...Technical Data 5 1 Technical data WA500 6H VEAM430100 5 3 GK032301 A B H I G C E F D...
Page 352: ...5 4 Limit values for slopes Technical Data 5 8 WA500 6H VEAM430100...
Page 401: ...Index WA500 6H VEAM430100 7 1 7 Index...
Page 407: ...Notes WA500 6H VEAM430100 8 1 8 Notes...
Page 408: ...Notes 8 2 WA500 6H VEAM430100...
Page 409: ...Notes WA500 6H VEAM430100 8 3...
Page 410: ...Notes 8 4 WA500 6H VEAM430100...
Page 411: ...Notes WA500 6H VEAM430100 8 5...
Page 412: ...Notes 8 6 WA500 6H VEAM430100...