Operation
3.7 Troubleshooting
WA500-6H – VEAM430100
3-181
Starting engine with booster cable
When starting the engine with a booster cable, do as follows:
Precautions when connecting and disconnecting booster
cable
WARNING
z
When connecting the cables, never contact the positive (+)
and negative (-) terminals.
z
When starting the engine with a booster cable, always wear
safety glasses and rubber gloves.
z
Be careful not to let the normal machine and problem
machine contact each other. This prevents sparks from gen-
erating near the battery which could ignite the hydrogen gas
given off by the battery.
z
Make sure that there is no mistake in the booster cable con-
nections. The final connection is to the engine block of the
problem machine, but sparks will be generated when this is
done, so connect to a place as far as possible from the bat-
tery.
z
When disconnecting the booster cable, take care not to bring
the clips in contact with each other or with the machine body.
NOTE
z
The size of the booster cable and clip should be suitable for
the battery size.
z
The battery of the normal machine must be the same capac-
ity as that of the engine to be started.
z
Check the cables and clips for damage or corrosion.
z
Make sure that the cables and clips are firmly connected.
z
Check that the work equipment lock levers and parking
brake levers of both machines are in the LOCK position.
z
Check that each lever is in the NEUTRAL position.
GK032231
Summary of Contents for WA500-6H
Page 2: ......
Page 3: ...Foreword WA500 6H VEAM430100 1 1 1 Foreword...
Page 26: ...1 7 CE Conforming equipment Foreword 1 24 WA500 6H VEAM430100...
Page 254: ...3 7 Troubleshooting Operation 3 188 WA500 6H VEAM430100...
Page 344: ...4 9 Service procedure Every 12000 hours service Maintenance 4 90 WA500 6H VEAM430100...
Page 345: ...Technical Data WA500 6H VEAM430100 5 1 5 Technical Data...
Page 347: ...Technical Data 5 1 Technical data WA500 6H VEAM430100 5 3 GK032301 A B H I G C E F D...
Page 352: ...5 4 Limit values for slopes Technical Data 5 8 WA500 6H VEAM430100...
Page 401: ...Index WA500 6H VEAM430100 7 1 7 Index...
Page 407: ...Notes WA500 6H VEAM430100 8 1 8 Notes...
Page 408: ...Notes 8 2 WA500 6H VEAM430100...
Page 409: ...Notes WA500 6H VEAM430100 8 3...
Page 410: ...Notes 8 4 WA500 6H VEAM430100...
Page 411: ...Notes WA500 6H VEAM430100 8 5...
Page 412: ...Notes 8 6 WA500 6H VEAM430100...