4.9 Service procedure
Initial 250 hours service (only after the first 250 hours)
Maintenance
4-28
WA500-6H – VEAM430100
4.9.2
Initial 250 hours service (only after the first 250 hours)
Carry out the following maintenance only after the first 250
hours.
Replace transmission oil filter element
For details, see "Replace transmission oil filter element (4-70)".
Replace hydraulic filter element
For details, see "Change oil in hydraulic tank, replace hydraulic
filter element (4-76)"
4.9.3
When required
Check, clean, or replace air cleaner element
WARNING
z
If inspection, cleaning, or maintenance is carried out with the
engine running, dirt will get into the engine and damage it.
Always stop the engine before carrying out these operations.
z
When using compressed air, there is danger that dirt may be
blown around and cause serious injury.
Always use safety glasses, dust mask, and other protective
equipment.
Checking
If air cleaner clogging caution lamp (1) on the machine monitor
lights up, clean the air cleaner element.
NOTE
Do not clean the element until the air cleaner clogging caution
lamp lights up.
If the element is cleaned frequently before the air cleaner clog-
ging caution lamp lights up, the air cleaner will not be able to dis-
play its performance fully and the cleaning efficiency will drop.
In addition, the frequency of dirt stuck to the element falling
inside the inner element will increase.
A dust indicator is installed inside the engine hood on the left
side of the machine. The dust indicator shows the condition of
clogging of the air cleaner in 5 stages. This makes it possible to
check how clean the element is and when it should be replaced.
GK050027
1
GK050097
Summary of Contents for WA500-6H
Page 2: ......
Page 3: ...Foreword WA500 6H VEAM430100 1 1 1 Foreword...
Page 26: ...1 7 CE Conforming equipment Foreword 1 24 WA500 6H VEAM430100...
Page 254: ...3 7 Troubleshooting Operation 3 188 WA500 6H VEAM430100...
Page 344: ...4 9 Service procedure Every 12000 hours service Maintenance 4 90 WA500 6H VEAM430100...
Page 345: ...Technical Data WA500 6H VEAM430100 5 1 5 Technical Data...
Page 347: ...Technical Data 5 1 Technical data WA500 6H VEAM430100 5 3 GK032301 A B H I G C E F D...
Page 352: ...5 4 Limit values for slopes Technical Data 5 8 WA500 6H VEAM430100...
Page 401: ...Index WA500 6H VEAM430100 7 1 7 Index...
Page 407: ...Notes WA500 6H VEAM430100 8 1 8 Notes...
Page 408: ...Notes 8 2 WA500 6H VEAM430100...
Page 409: ...Notes WA500 6H VEAM430100 8 3...
Page 410: ...Notes 8 4 WA500 6H VEAM430100...
Page 411: ...Notes WA500 6H VEAM430100 8 5...
Page 412: ...Notes 8 6 WA500 6H VEAM430100...