4.9 Service procedure
Maintenance
Every 2000 hours service
WA500-6H – VEAM430100
4-79
Replace hydraulic tank breather element
WARNING
z
The parts and oil are at high temperature after the engine is
stopped, and may cause burns. Wait for the temperature to
go down before starting the work.
z
When removing the oil filler cap, turn it slowly to release the
internal pressure, then remove it.
1. Lower the bucket horizontally to the ground and turn the
parking brake switch ON.
2. Stop the engine and wait for the temperature at all parts to
go down.
3. Remove the cap of oil filler (F).
4. Remove the snap ring from breather (1), then remove the
breather cap.
5. Replace the filter element with a new part, then install the
breather cap and snap ring.
6. Tighten the cap of oil filler (F).
REMARK
It is possible to replace the element with the breather installed in
the tank. However, if the breather is removed, do not wrap the
taper thread of the breather with seal tape when assembling
again, and be careful not to tighten too much.
GK050214
1
F
Summary of Contents for WA500-6H
Page 2: ......
Page 3: ...Foreword WA500 6H VEAM430100 1 1 1 Foreword...
Page 26: ...1 7 CE Conforming equipment Foreword 1 24 WA500 6H VEAM430100...
Page 254: ...3 7 Troubleshooting Operation 3 188 WA500 6H VEAM430100...
Page 344: ...4 9 Service procedure Every 12000 hours service Maintenance 4 90 WA500 6H VEAM430100...
Page 345: ...Technical Data WA500 6H VEAM430100 5 1 5 Technical Data...
Page 347: ...Technical Data 5 1 Technical data WA500 6H VEAM430100 5 3 GK032301 A B H I G C E F D...
Page 352: ...5 4 Limit values for slopes Technical Data 5 8 WA500 6H VEAM430100...
Page 401: ...Index WA500 6H VEAM430100 7 1 7 Index...
Page 407: ...Notes WA500 6H VEAM430100 8 1 8 Notes...
Page 408: ...Notes 8 2 WA500 6H VEAM430100...
Page 409: ...Notes WA500 6H VEAM430100 8 3...
Page 410: ...Notes 8 4 WA500 6H VEAM430100...
Page 411: ...Notes WA500 6H VEAM430100 8 5...
Page 412: ...Notes 8 6 WA500 6H VEAM430100...