4.9 Service procedure
When required
Maintenance
4-32
WA500-6H – VEAM430100
To maintain the anticorrosion properties of Supercoolant (AF-
NAC), always keep the density of Supercoolant between 30%
and 68%.
When using KOMATSU Supercoolant (AF-NAC), there is no
need to use a corrosion resistor.
When no corrosion resistor is used, use the special cover (600-
411-9000). Please consult your KOMATSU distributor about the
method of installing.
When deciding the ratio of antifreeze to water, check the lowest
temperature in the past, and decide from the mixing table given
below.
It is actually better to estimate a temperature about 10°C (18°F)
lower when deciding the mixing rate.
The mixing ratio depends on the ambient temperature, but it
should always be a minimum of 30% by volume (antifreeze/total
amount of coolant x 100).
The freezing temperature of undiluted antifreeze is -15°C (5°F).
Do not store undiluted antifreeze at a temperature of below -
15°C (5°F).
Mixing rate of water and antifreeze
If the jobsite changes frequently and it is difficult to manage the
density of the antifreeze, a density of up to 50% can be permit-
ted.
Min. atmospheric
temperature
°C
-10
-15
-20
-25
-30
°F
14
5
-4
-13
-22
Amount of
antifreeze
Liter
36
43
49
55
60
US gal
9.51
11.41
13.00
14.58
15.85
Amount of water
Liter
84
77
71
65
60
US gal
22.29
20.29
18.70
17.12
15.85
Ratio
%
30
36
41
46
50
Summary of Contents for WA500-6H
Page 2: ......
Page 3: ...Foreword WA500 6H VEAM430100 1 1 1 Foreword...
Page 26: ...1 7 CE Conforming equipment Foreword 1 24 WA500 6H VEAM430100...
Page 254: ...3 7 Troubleshooting Operation 3 188 WA500 6H VEAM430100...
Page 344: ...4 9 Service procedure Every 12000 hours service Maintenance 4 90 WA500 6H VEAM430100...
Page 345: ...Technical Data WA500 6H VEAM430100 5 1 5 Technical Data...
Page 347: ...Technical Data 5 1 Technical data WA500 6H VEAM430100 5 3 GK032301 A B H I G C E F D...
Page 352: ...5 4 Limit values for slopes Technical Data 5 8 WA500 6H VEAM430100...
Page 401: ...Index WA500 6H VEAM430100 7 1 7 Index...
Page 407: ...Notes WA500 6H VEAM430100 8 1 8 Notes...
Page 408: ...Notes 8 2 WA500 6H VEAM430100...
Page 409: ...Notes WA500 6H VEAM430100 8 3...
Page 410: ...Notes 8 4 WA500 6H VEAM430100...
Page 411: ...Notes WA500 6H VEAM430100 8 5...
Page 412: ...Notes 8 6 WA500 6H VEAM430100...