5-4
INTERFERENCE FILTER
Refer to page 4-13 for the procedure for ac-
cessing the interference filter.
1. Unplug washer or disconnect power.
2. Disconnect the wire connectors from the
interference filter terminals.
3. Set the ohmmeter to the R X 10K scale.
4. Touch the ohmmeter test leads to the in-
terference filter connector pins. The meter
should indicate approximately 450K
Ω
.
DRAIN PUMP MOTOR
Refer to page 4-18 for the procedure for ac-
cessing the drain pump assembly.
1. Unplug washer or disconnect power.
2. Disconnect the drain pump motor connec-
tor from the CCU.
3. Set the ohmmeter to the R X 1 scale.
4. Touch the ohmmeter test leads to the two
drain pump motor connector pins. The
meter should indicate 15
Ω
.
Motor
Terminals
2 1
(Connector Viewed From Wire End)
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
WARNING