4-30
REASSEMBLY NOTES:
1. When reassembling the tub, install the
tub clamps over the flanges of the two tub
sections with a hammer.
Tub Flanges
2. When reinstalling the tub assembly, hook
the two suspension springs into the front
holes of the tub and the rear slots of the
cabinet.
3. When reinstalling the bottom front coun-
terweight, first tape the flat nut in place in
the tub slot so it does not fall out.
Bottom Front Counterweight Flat Nut
4. When reinstalling the heating element in
the tub, make sure that it is held in place
by the wire holder (see the photo in step
27 on the previous page).
5. After reinstalling the tub, install two new
wire ties around the standoffs (see step
16 on page 4-27).
Tub Clamp
Rear Slot
Rear Slot
Front Holes
Heating
Element