4-18
Front Pump
Mount Removed
REMOVING THE DRAIN PUMP ASSEMBLY
1. Unplug washer or disconnect power.
2. Turn off the water supply to the washer.
3. Remove the toe panel (see page 4-5 for
the procedure).
4. Unclip the end of the drain tube and drain the
water from the drain pump into a container.
Drain Pump Assembly
5. Raise the drain pump wiring cover and
disconnect the wire connector.
6. Pull the drain tube out of the clamp.
7. Pull the front pump mount from the front
of the pump, then remove the mount from
the chassis keyhole slot.
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
WARNING
Wiring Cover
Pump Wire Connector
8. Tip the drain pump back so the two rear
pump mount stops are out of their chassis
slots, then pull the pump forward to remove
the mounts from the slots, and remove the
pump.
Front Pump Mount
Rear Pump Mounts
Drain Tube Clamp
Drain Tube Clips