5-2
DETERGENT DISPENSER
MOTOR & SWITCH
Refer to page 4-7 for the procedure for access-
ing the detergent dispenser motor.
1. Unplug washer or disconnect power.
2. Disconnect the detergent dispenser motor
and switch connector from the CCU.
3. Set the ohmmeter to the R X 100 scale.
4. Touch the ohmmeter test leads to the
indicated wire connector pins. The meter
should indicate as follows:
Dispenser motor at pins 1 and 3 = 1400
to 1600
Ω
.
Dispenser switch at pins 5 and 6 = 0
Ω
.
Refer to page 4-10 for the procedure for ac-
cessing the inlet valves.
1. Unplug washer or disconnect power.
2. Disconnect the inlet valve solenoid con-
nector from the CCU.
3. Set the ohmmeter to the R X 100 scale.
4. Touch the ohmmeter test leads to the
following wire connector pins. The meter
should indicate between 750 and 850
Ω
.
• Cold Water Solenoid = pins 1 and 3.
• Hot Water Solenoid = pins 5 and 7
INLET VALVE SOLENOIDS
HOT COLD
7 5 3 1
65 3 1
(Connector Viewed From Wire End)
(Connector Viewed From Wire End)
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
WARNING