24
EN
4. Control unit setting
4.1 - Dip-switch adjustment
DIP
DIP-SWITCH status
Description
DIP 1-2
MOTOR
m
1 ON 2 ON
Connected gearmotors: swing gate series “Jet 24V”, “JetXL 24V”, “Linear 24V”, “Intro 24-400” or
“Couper24”
1 ON 2 OFF
Connected gearmotors: swing gate series “Modus”
1 OFF 2 ON
Connected gearmotor: sliding gate series “Dynamos”
1OFF 2 OFF
Connected gearmotor: swing gate series “Minimodus”
DIP 3
STEP
3 ON 4 OFF
Step-by-step command mode: Open / Stop / Close / Stop
3 ON 4 ON
Step-by-step with automatic closing (time set with the “Pause” knob)
DIP 4
AUTO
3 OFF 4 ON
Opening only command mode with automatic closing (condominium function)
3 OFF 4 OFF
Open / Close / Open command mode (no Stop)
DIP 5
PHO2
ON
Devices connected to PHO2 set as photocells (stop of the movement both in opening
and closing phases with opening manoeuvre after PHO2 clearance)
OFF
Devices connected to PHO2 set as edges (immediate inversion; active just in opening phase)
DIP 6
HAZ
ON
Warning light flashing during cycle
OFF
Warning light on during cycle
DIP 7
FAST
ON
Gate recloses immediately after vehicle passes PHO1 devices (photocells)
OFF
Standard operation - devices (photocells/safety edges) do not command a reclosing manoeuvre
DIP 8
FUNC
SWING
(see DIP 1-2)
ON
Ram function enabled
OFF
Ram function disabled
SLIDING
(see DIP 1-2)
ON
Reverse opening direction (automation’s movement must be programmed afterwards)
OFF
Reverse opening direction (automation’s movement must be programmed afterwards)
1
23
45
6
78
1
8
ON
Summary of Contents for STARG8 24NG
Page 111: ......