36
EN
16.2 - Activating/deactivating start
and pedestrian security mode
Default = wired start input and start button of the control
unit are activated.
This programming sequence allows for better security by
disabling the operation of the START / PED wired input and the
start button on the control unit. The control unit is now activated
with the transmitter only.
1.
PRESS THE
START
BUTTON FOR 3 SECONDS: all leds turn
OFF (if not, consult Paragraph 17.1)
2.
PRESS THE
SET
BUTTON FOR 1 SECOND
- If the
ERROR
led is ON
security = activated (if the setting is correct, go to Point 5; if
not, proceed to Point 3)
- If the
ERROR
led is OFF
security = deactivated (if the setting is correct, go to Point
5; if not, proceed to Point 4)
3.
PRESS THE
START
BUTTON FOR 1 SECOND: the
SET
led
remains lit and the
ERROR
led turns OFF. Go to step 5
4.
PRESS THE
START
BUTTON FOR 1 SECOND: the
SET
led
remains lit and the
ERROR
led turns ON
5.
PRESS THE
SET
AND
RADIO
BUTTONS
SIMULTANEOUSLY OR WAIT 10 SECONDS TO EXIT THE
PROCEDURE: the leds return to the normal operation
configuration
m
If the security command lock is activated, any device
connected to the START and PED contacts will not be
detected by the control unit. When these contacts are
closed, the START led will emit brief flashes.
17. Other functions
m
To interrupt the following programming sequences at
any time, press the SET and RADIO buttons simultaneously
or wait 10 seconds.
17.1 - Activating/deactivating the
control unit protection device
Default = control unit protection device not active.
m
This programming sequence allows for locking all
control unit programming sequences and the settings
adjustable through the dip-switches. To perform a new
programming sequence or make a dip-switch/trimmer
modification effective, the protection must be deactivated.
Advanced programming (not required for standard installations)
1.
PRESS THE
START
BUTTON FOR 3 SECONDS:
- if the leds
SET
,
RADIO
and
START
are ON
control unit lock = enabled (if it is the correct setting, go to
step 4, otherwise proceed to step 2)
- If the leds
SET
,
RADIO
and
START
are OFF
control unit lock = disabled (if it is the correct setting, go to
step 4, otherwise proceed to step 3)
2.
PRESS BOTH BUTTONS
START
AND
RADIO
, FOR 2
SECONDS: the leds
SET
,
RADIO
and
START
go OFF.
Go to step 4
3.
PRESS BOTH BUTTONS
START
AND
RADIO
, FOR 2
SECONDS: the leds
SET
,
RADIO
and
START
go ON
4.
PRESS THE
SET
AND
RADIO
BUTTONS
SIMULTANEOUSLY OR WAIT 10 SECONDS TO EXIT THE
PROCEDURE: the leds return to the normal operation
configuration
17.2 - Energy saving mode
This feature cuts the power supply to the photocells when the
control unit is on standby, therefore it decreases the power
consumption. It is useful in case of battery power supply
conditions.
m
When the energy saving mode is activated, the open
gate pilot light function is deactivated (Paragraph 9.7)
m
The energy saving mode can only be used with safety
accessories powered with 24VDC.
1.
PRESS THE
START
BUTTON FOR 4 SECONDS: all leds turn
OFF (if not, consult Paragraph 17.1)
2.
SIMULTANEOUSLY PRESS THE
SET
AND
START
BUTTONS FOR 2 SECONDS:
- If the led
PHOTO
is ON
Energy saving = enabled (if it is the correct setting, go to
step 5 otherwise proceed to step 4)
- If the red led
PHOTO
is OFF
Energy saving = disabled (if it is the correct setting, go to
step 5 otherwise proceed to step 4)
3.
PRESS THE
SET
BUTTON FOR 1 SECOND: the led
SET
and
the
START
are ON, while the led
PHOTO
turns OFF.
Go to step 5
4.
PRESS THE
SET
BUTTON FOR 1 SECOND: the led
SET
and
the
START
are ON, while the led
PHOTO
turns ON
5.
PRESS THE
SET
AND
RADIO
BUTTONS
SIMULTANEOUSLY OR WAIT 10 SECONDS TO EXIT THE
PROCEDURE: the leds return to the normal operation
configuration
m
Connection of accessories with the energy saving
mode activated
Once the function is activated, it is necessary to connect the
24VDC positive pole of the safety accessories (for example:
photocells) to terminal GSI. The control devices (e.g.: receivers,
spires or photocells connected to the Start contact) must be
connected to teVA.
m
If DIP-SWITCH 7 FAST is put to ON, with the control
unit open the accessories remain powered to retain the re-
closing function.
m
If you activate the power saving mode all the LEDs
will turn OFF after 2 minutes of stand-by.