A variation of DIP 1-2 MOTOR and DIP 8 FUNC (if the
control unit is set to sliding gate) will not become effective
until a new gate path is programmed (Paragraph 6).
DIP1-2 MOTOR:
Set those DIP switches to suit the type of motors in use for this
installation.
DIP3 STEP:
ON
-
step by step, a command will open, stop, or close the gate
OFF
- setup for fully automatic, condominium ( apartment block )
DIP4 AUTO:
ON
- the automatic re-closing function is activated. The control
unit automatically closes the leaves after the time set through the
PAUSE knob (see Paragraph 4.2).
OFF
- the automatic re-closing function is deactivated. To close
the leaves, therefore, a command must be given (either wired or
via transmitter).
DIP5 PHO2:
ON
- Gate will stop on opening and closing ( for photocells )
OFF
- Gate will stop in opening and reverse direction immediately
(for safety edge)
DIP6 HAZ:
ON
-
the warning light is powered in the intermittent mode.
OFF
- power to the flasher is constant.
DIP7 FAST:
ON
- the rapid reclosing function is activated. In this mode, the
gate will close as soon as the gate photocells connected to PHO1
input are obscured and cleared without waiting for the pause
time.
OFF
- the rapid reclosing function is deactivated.
DIP8 FUNC:
SWING GATE (DIP1/2= ON ON / ON OFF/ OFF OFF)
ON
- this activates the ram function, which is recommended if an
electric lock is installed (par. 10.5). This delivers a transient
voltage
peak at the start of the opening stroke and the end of the closing
stroke to overcome the resistance of the pawl.
OFF
- the ram function is disabled.
SLIDING GATE (DIP1/2= OFF/ON)
Changing the position of the FUNC dip switch changes the
opening stroke direction. This becomes effective at the beginning
of basic or advanced programming of automation’s movement.
4.2 - Knob adjustment
POWER
: Power: adjustment of motor power and speed. Turning
the knob clockwise increases the motor’s power and speed.
To validate the modification it is necessary to programme
again the gate travel.
OBS:
Obstacle, (sensitivity to obstacles): adjustment of the
obstacle detection function. Turning the knob clockwise increases
time before obstacle detection (less sensitivity). OBSTACLE set
at half position (50%) corresponds to 0,75 seconds of pushing
against an obstacle before reversing the movement.
It is advisable to keep OBSTACLE above the middle to
obtain reliable operation over time with normal changes in
environmental and mechanical conditions.
PAUSE:
Pause time before automatic gate closing. Turning the
knob clockwise increases the pause time from 0 to 180
seconds. Please note: this knob is functional only when AUTO
dip-switch 4 is put to ON.
DELAY:
Adjustment of the delay in movement between the two
gate wings. Turning the knob clockwise increases the
delay from 0 to 20 seconds.
Open delay is half of closure delay (motor 1 starts opening and
motor 2 waits half delay value).
DELAY at maximum value: motor 2 waits total open of motor 1.
Motor 1 waits total close of motor 2.
m
After adjusting the POWER knob, it’s necessary to
programme again the gate travel. (par.5).
m
In normal operation, gate leaves must be offset
to prevent overlapping. If the DELAY knob is set too
low and leaf 1 arrives before leaf 2, the control unit will
automatically open the gate slightly and then close leaves
in the correct order (anti-overlapping mechanism).
1
23
45
6
78
MAX
DELAY
PAUSE
OBSTACLE
POWER