35
EN
Advanced programming (not required for standard installations)
15.2 - Selection of the outputs linked
to the photo-test
Default = PHO1 and PHO2 contacts
With this procedure, it is possible to decide on which devices to
carry out the photo-test.
1.
PRESS THE
START
BUTTON FOR 3 SECONDS: all leds turn
OFF (if not, consult Paragraph 17.1)
2.
PRESS THE
START
BUTTON FOR 1 SECOND
- If the
STOP
led is ON
photo-test = ON PHO1 and PHO2 contacts (if the setting is
correct, go to Point 5; if not, proceed to Point 3)
- If the
STOP
led is OFF
photo-test = ON PHO1 contact (if the setting is correct, go
to Point 5; if not, proceed to Point 4)
3.
PRESS THE
RADIO
BUTTON FOR 1 SECOND: the
START
led remains ON and the
STOP
led turns OFF. Go to step 5
4.
PRESS THE
RADIO
BUTTON FOR 1 SECOND: the
START
led remains ON and the
STOP
led turns ON
5.
PRESS THE
SET
AND
RADIO
BUTTONS
SIMULTANEOUSLY OR WAIT 10 SECONDS TO EXIT THE
PROCEDURE: the leds return to the normal operation
configuration
m
The photo-test can only work with photocells
powered at 24VDC.
15.3 - Selection of the type of devices
linked to PHO2
Default = PHO2 set for devices with normally closed
contact
This procedure allows for setting the PHO2 output for managing
8.2kOhm resistive edges.
The control unit constantly verifies the integrity of the edge by
measuring the resistance between the two dedicated terminals.
1.
PRESS THE
START
BUTTON FOR 3 SECONDS: all leds turn
OFF (if not, consult Paragraph 17.1)
2.
PRESS THE
START
BUTTON FOR 1 SECOND
- If the
ERROR
led is ON
PHO2 = resistive edge (if the setting is correct, go to Point
5; if not, proceed to Point 4)
- If the
ERROR
led is OFF
PHO2 = device with normally closed (NC) contact (if the
setting is correct, go to Point 5; if not, proceed to Point 4)
3.
PRESS THE
START
BUTTON FOR 1 SECOND: the
START
led remains ON and the
ERROR
led turns OFF. Go to step 5
4.
PRESS THE
START
BUTTON FOR 1 SECOND: the
START
led remains ON and the
ERROR
led turns ON
5.
PRESS THE
SET
AND
RADIO
BUTTONS
SIMULTANEOUSLY OR WAIT 10 SECONDS TO EXIT THE
PROCEDURE: the leds return to the normal operation
configuration
m
The connected edges must be of the resistive type
with 8.2 kOhm.
16. Setting the wired
commands
These programming sequences allow:
1) for locking wired commands, ONLY transmitters working
2) changing the wired commands start and pedestrian inputs to
OPEN and CLOSE
m
If, at the start of the following procedures, the
SET, RADIO and START LEDs flash, it means that the
programming protection has been activated – see
Paragraph 17.1.
m
To interrupt the following programming sequences at
any time, press the SET and RADIO buttons simultaneously
or wait 10 seconds.
16.1 - Selecting the wired command
modes
Default = START function as per the setup of dip-switches
3.4.7 ( see section 4.1 ) and PED is a partial opening
command.
This programming changes the commands START become open
only and PED becomes close only.
1.
PRESS THE
START
BUTTON FOR 3 SECONDS: all leds turn
OFF (if not, consult Paragraph 17.1)
2.
PRESS THE
SET
BUTTON FOR 1 SECOND:
- If the
STOP
led is ON
always open/only close mode (if the setting is correct, go to
Point 5; if not, proceed to Point 3)
- If the
STOP
led is OFF
start/ped mode (default) (if the setting is correct, go to Point
5; if not, proceed to Point 4)
3.
PRESS THE
RADIO
BUTTON FOR 1 SECOND: the
SET
led
remains lit and the
STOP
led turns OFF. Go to step 5
4.
PRESS THE
RADIO
BUTTON FOR 1 SECOND: the
SET
led
remains lit and the
STOP
led turns ON
5.
PRESS THE
SET
AND
RADIO
BUTTONS
SIMULTANEOUSLY OR WAIT 10 SECONDS TO EXIT THE
PROCEDURE: the leds return to the normal operation
configuration
m
For controlling the automation also via radio with
separate open/close commands, an external radio receiver
must be installed.
m
If you enable the mode “open / close”, the dip STEP
will affect only the radio commands.
Summary of Contents for STARG8 24NG
Page 111: ......