15. Photocells and
safety edges advanced
programming sequences
These programming sequences are not essential to the system’s
operation, but they allow for controlling the devices by activating
the photo-test—when photocells are installed—or controlling the
resistance when 8.2kOhm resistive edges are mounted.
m
To interrupt the following programming sequences at
any time, press the SET and RADIO buttons simultaneously
or wait 10 seconds.
15.1 - Photo-test activation/
deactivation
Default= deactivated
The photo-test is a check aimed at verifying whether the 24VDC-
powegreen photocells function properly.
It consists in cutting off the power supply to the transmitter
photocell (TX) from the control unit, while subsequently verifying
that the contact (PHO1, or PHO1 and PHO2, depending on the
settings in Paragraph 15.2) opens. Subsequently, the control unit
restores the power supply to the transmitter photocell and verifies
that the contact closes.
This occurs before each movement of the automation.
For the test to work, the photocells must be wired
according to the following scheme:
+24V RX photocell = teVA
+24V TX photocell = terminal GSI
m
The photo-test can only work with photocells
powered at 24VDC.
m
By default the phototest function works on both
contacts PHO1 and PHO2. To set this test only on the
contact PHO1, please see paragraph 15.2.
m
By enabling the photocells test, you will lose the “gate
status indicator” function (GSI).
m
If PHO2 is set as safety edge (DIP 5 OFF) the
phototest will only be active on contact PHO1.
1.
PRESS THE
START
BUTTON FOR 3 SECONDS: all leds turn
OFF (if not, consult Paragraph 17.1)
2.
PRESS THE
START
BUTTON FOR 1 SECOND
- If the
PHOTO
led is ON
photo-test = activated (if the setting is correct, go to Point
5; if not, proceed to Point 3)
- If the
PHOTO
led is OFF
photo-test = deactivated (if the setting is correct, go to
Point 5; if not, proceed to Point 4)
3.
PRESS THE
SET
BUTTON FOR 1 SECOND: the
START
ledremains ON and the
PHOTO
led turns OFF. Go to step 5
4.
PRESS THE
SET
BUTTON FOR 1 SECOND: the
START
led
remains ON and the
PHOTO
led turns ON
5.
PRESS THE
SET
AND
RADIO
BUTTONS
SIMULTANEOUSLY OR WAIT 10 SECONDS TO EXIT THE
PROCEDURE: the leds return to the normal operation
configuration
Advanced programming (not required for standard installations)
14.2 - Voltage for the AUX output
m
Warning: the Aux output voltage is a division of the
accessory voltage, with a peak value higher than 24V
Default=12VDC
The output voltage of the AUX contact can be set to 12VDC or
24VDC, depending on the connected lock or the available relay.
1.
PRESS THE
START
BUTTON FOR 3 SECONDS: all leds turn
OFF (if not, consult Paragraph 17.1)
2.
PRESS THE
RADIO
BUTTON FOR 1 SECOND
- If the
ERROR
led is ON
AUX voltage = 12VDC (if the setting is correct, go to Point
5; if not, proceed to Point 3)
- If the
ERROR
led is OFF
AUX voltage = 24VDC (if the setting is correct, go to Point
5; if not, proceed to Point 4)
3.
PRESS THE
START
BUTTON FOR 1 SECOND: the
RADIO
led remains lit and the
ERROR
led turns OFF. Go to step 5
4.
PRESS THE
START
BUTTON FOR 1 SECOND: the
RADIO
led remains lit and the
ERROR
led turns OFF
5.
PRESS THE
SET
AND
RADIO
BUTTONS
SIMULTANEOUSLY OR WAIT 10 SECONDS TO EXIT THE
PROCEDURE: the leds return to the normal operation
configuration
14.3 - Programming of the button
linked to the AUX output
This procedure allows for programming the button of the radio
control linked to the AUX output.
To use this function, the AUX output must be set to courtesy light
– see Paragraph 14.2.
1.
PRESS THE
RADIO
BUTTON FOR 1 SECOND: the
RADIO
led turns ON
2.
PRESS THE
SET
BUTTON FOR 1 SECOND: the
RADIO
led
remains lit and the
SET
led turns ON
3.
PRESS THE DESIRED BUTTON OF ALL THE
TRANSMITTERS TO BE PROGRAMMED: the
RADIO
led
flashes and the
SET
led remains ON
4.
PRESS THE
SET
AND
RADIO
BUTTONS
SIMULTANEOUSLY OR WAIT 10 SECONDS TO EXIT THE
PROCEDURE: the
RADIO
led and the
SET
led turn OFF