33
EN
13. Backjump adjustment
This procedure allows for adjusting or eliminating the backjump
function.
Backjump is inverting the gate movement at the end of the travel
to facilitate easy unlocking and manual release as well as to
safeguard the mechanical system. On certain motors backjump is
unnecessary, therefore the value is set to 1 by default. On certain
motors backjump is compulsory and therefore default is set to 2.
DEFAULT:
Jet, Couper, Intro or Dynamos motors (see dip-switch 1 and 2
settings) backjump = value 1
Minimodus motors (see dip-switch 1 and 2 settings) = value 2
Modus motors (see dip-switch 1 and 2 settings) = value 2
m
Prior to proceeding with this programming procedure,
first verify whether either the “basic path programming” or
the “advanced path programming” have been completed.
1.
PUT THE GATE LEAF/LEAVES IN THE CLOSED POSITION
2.
PRESS THE
START
BUTTON FOR 3 SECONDS: all the leds
turn OFF (if not, consult Paragraph 17.1)
3.
PRESS THE
SET
BUTTON FOR 1 SECOND: the
SET
led
turns ON and the
PHOTO
led indicates the backjump* level
4.
PRESS THE
SET
BUTTON FOR 1 SECOND: the
SET
led
flashes then turns ON and the
PHOTO
led flashes, indicating
the backjump* level
5.
EVERY TIME THE
SET
BUTTON IS PRESSED, THE
VALUE CHANGES FROM 1 TO 6 STARTING FROM THE
CURRENTLY
SET
VALUE: the
SET
led remains ON and the
PHOTO
led flashes, indicating the backjump* level
6.
PRESS THE
RADIO
BUTTON FOR 2 SECONDS: the
SET
led
remains ON steady and the
ERROR
led flashes quickly
7.
PRESS THE
SET
AND
RADIO
BUTTONS
SIMULTANEOUSLY OR WAIT 10 SECONDS TO EXIT THE
PROCEDURE: the leds return to the normal operation
configuration
* The backjump value is indicated by the number of flashes of the
PHOTO led series, based on the set value.
When the series consists of one flash, the backjump value is zero
(no inversion of movement at end-of-path), when there are 6
flashes, the backjump is set to the maximum value.
Clearly, the other series indicate growing intermediate values from
1 to 6.
The backjump value can be seen at any time after the SET button
is pressed the first time, by counting the number of flashes of the
green PHOTO led.
Max
0
6
Inversion
time
1
m
If the backjump value is set too high, some undesired
clearance may remain between the door and the
mechanical stop.
14. AUX output programming
m
To interrupt the following programming sequences at
any time, press the SET and RADIO buttons simultaneously
or wait 10 seconds.
m
If, at the start of this procedure, the SET, RADIO
and START LEDs flash, it means that the programming
protection has been activated – see Paragraph 17.1.
14.1 - Operating mode for the AUX
output
m
Warning:
• Depending on the load applied, it may be necessary to
connect a relay with a separate power supply
• The resistive load applicable to the AUX terminal must
absorb a maximum of 24W
• The operating modes of the AUX output are mutually
exclusive
The output to the AUX terminal can take on the following
functions:
- Electric lock relay output: at each START command, the
output activates for 2s
- Electric lock output: the output remains active only with the
gate closed
- Timed output (2seconds) piloted by remote control
- ON-OFF output controlled by remote control: the output turns
ON and OFF only via remote control
1.
PRESS THE
RADIO
BUTTON FOR 3 SECOND: the
RADIO
led turns on steadily (if not, see par.17.1)
2.
PRESS THE
RADIO
BUTTON FOR 1 SECOND:
The
STOP
led flashes
1
flash AUX = electric lock
2
flashes AUX = electric lock
3
flashes AUX = Monostable by time (2 seconds by default)
piloted by remote control button
4
flashes AUX = Bistable ON-OFF from remote control button
3.
PRESS THE
SET
BUTTON FOR 1 SECOND: THE AUX
OUTPUT SWITCHES TO THE NEXT FUNCTION: the
STOP
led flashes indicating the set function
4.
PRESS THE
SET
AND
RADIO
BUTTONS
SIMULTANEOUSLY OR WAIT 10 SECONDS TO EXIT THE
PROCEDURE: the
RADIO
led and the
SET
led turn OFF
Advanced programming (not required for standard installations)
Summary of Contents for STARG8 24NG