Keysight U3810 Series Getting Started Guide
71
Schematic and Characteristics of Sensors and Actuators
Relay Actuator
Parameter
Minimum
Maximum
Typical
Units
Condition
VCC
4.0
5.5
5.0
Volts
Iin
2.0
4.0
3.0
mA
Relay Off
Iin
55.0
90
71.0
mA
Relay On
Vinh
2.1
VCC+0.7
Volts
Input to turn off relay
Vinl
-0.7
1.8
Volts
Input to turn on relay
Operate time
15
ms
Release time
5
ms
Rinitial
50
m
Ω
Life expectancy
10
7
ops
< 1A contact current
Summary of Contents for U3810A