Keysight U3810 Series Getting Started Guide
101
7
Type something in the
Console log
of either the gateway or sensor node Zigbee, and then do it
again with the other module. You should see the same message appear in the other Zigbee
module. This verifies that both Zigbee modules are communicating with each other.
HINT: No
Console Log
? Ensure AP API Enable parameter is set to Transparent Mode [0] on both
XBees.
Sensor node Zigbee console:
Gateway Zigbee console:
NOTE
If the Zigbee modules are not able to communicate to each other, assure that:
–
All the settings are set correctly as per the instructions.
–
The value for Zigbee Stack Profile (ZS) is the same for both Zigbee modules.
–
Assure that the PAN ID (ID) and Scan Channel (SC) of the sensor node Zigbee is set to
the OP and SC of the gateway Zigbee.
–
Rarely after previously successful connection is established, the Zigbee connection
may not reconnect. If this is the case, try temporarily reversing the CE Device Role of
the two devices in place, complete the connection, and then reversing again.
If the above steps do not work, the XBee firmware may need to be updated and made
consistent for all Zigbee transceivers.