Keysight U3810 Series Getting Started Guide
56
In this section, you are going to test run a ready-made application to capture returned data from the
TMP36 analog temperature sensor and display the results on the LCD. The TMP36 analog
temperature sensor is a precision integrated-circuit temperature device that operates at 2.7 to 5.5 V
and produces an output voltage linearly proportional to the temperature. It measures temperature
from -50 °C to 150 °C and produces output voltages from 0.0 to 2.0 Volts. Every 10-mV change in
the output voltage represents a temperature change of 1 °C. The TMP36 is based at .5V where 0’C =
500mV
V
TMP36
= .5V + Temp x .01V/C
The schematic of the connection is shown below, with the sensor connected to CH7 (A7):