DC/DC Converter and Charger
Parameter
Minimum
Maximum
Typical
Units
Condition
DCDC Input
2.4
25
Volts
Fixed or high efficiency Burst mode
DCDC Output
3.7/5/11
Volts
Selectable
MPPC Operating
Point range
2.4
16
Volts
Set with potentiometer R1904
Charger Input
2.7
25
Volts
One-shot mode
Charger Output
3.3/4.2/9.8
Volts
Selectable
For charging 2xNiMH/1xLiPo/1x NiMH
Charger Output
2.5/100/250
mA
Selectable
Current should be < C (mA-hr.)/10