Operating and Appliance Displays
Adr.
min
max
default
2C02h
0,0125
Hz
409,5875
409,5875
0
Adr.
min
max
default
2C03h
Adr.
min
max
default
2C04h
Adr.
min
max
default
2C05h
Adr.
min
max
default
2C06h
1
-
-
9999
0
0,1
-
-
-
-
1
-
-
Software
Software
Display of the maximum possible output frequency in Hz for this inverter. The value range and the resolution depend on
ud.11.
In. 2
Max. output frequency
1
kHz
LTK
LTK
1
Display of the maximum possible carrier frequency in kHz for this inverter. The default and maximum values depend on
the power circuit identification (LTK).
In. 3
Max. carrier frequency
This parameter contains the code for the software version number and the control hardware.
1st digit:
Control hardware ( 0 = 00.F4, A = 0A.F4, D = 0D.F4 )
2nd and 3rd digit:
Software version ( e.g. 11 = 1.1 )
4th digit:
Special version ( 0 = Standard)
In. 4
Software identification
Display of the software date. It contains day, month and year, however only the last number of the year is displayed.
Example:
Display
= 1507.8
date
= 15.07.98 / 15th July 1998
In. 5
Software date
This parameter serves for the identification of the software used in the control through KEB COMBIVIS. The configuration
takes place automatically at the call of COMBIVIS and connected inverter.
In. 6
Config-file number