6
1
Name: Basis
KEB COMBIVERT F4-C
14
09.04.99
©
KEB Antriebstechnik, 1999
All Rights reserved
Functional Description
Chapter
Section
Page
Date
Operating and Appliance Displays
Adr.
min
max
default
Adr.
min
max
default
Adr.
min
max
default
Adr.
min
max
default
Adr.
min
max
default
2021h
ru.33 Display counter A
0,01
s / h
-
327,67
0
The counter content of the free-to-program counter A is displayed, alternatively in seconds or hours (see LE.47). The
counter can be adjusted to any chosen value by means of keyboard or bus. The programming of the counter is done
with the parameters LE.41…LE.47.
2022h
ru.34 Motorpoti - current value
0,01
%
0
100
-100
The motor-poti function in the KEB COMBIVERT simulates a mechanic, motor-driven potentiometer. The triggering is
done over 2 programmable inputs („Poti up“ and „Poti down“). The display (-100…100%) relates to the fixed limits
(oP.4…oP.7). In addition to the inputs the motor-poti can also be triggered with the keys „UP“ and „DOWN“. By bus the
motor-poti can be set to any chosen value between -100…100%. The adjustment of the motor-poti is done with the
parameters oP.26…oP.29.
2029h
ru.41 Analog output 1 display
(terminal X1.15)
0,1
%
-
100
0
This parameter shows the percentual value of the output signal at the analog output AOUT (terminal X1.15). An output
signal of 0…10V corresponds to 0…100%.
202Bh
ru.43 Programmable display
-
-
-
32767
-32767
Contrary to the fixed defined indications, this display is free for own definitions. Thus a customer-specific value (e.g.
bottles/min) can be displayed. The definition is done with ud.87…ud.91.
202Ch
ru.44 Carrier frequency display
1
kHz
-
16
1
Displays the current operating frequency of the inverter.