![KEB COMBIVERT F4-C Applications Manual Download Page 180](http://html1.mh-extra.com/html/keb/combivert-f4-c/combivert-f4-c_applications-manual_3852415180.webp)
15
ANTRIEBSTECHNIK
6
9
15
KEB COMBIVERT F4-C
Name: Basis
29.01.98
6
ANTRIEBSTECHNIK
Section
Page
Date
©
KEB Antriebstechnik, 1997
All Rights reserved
Chapter
Functional Description
Special Functions
Param.
Adr.
min
max
default
ENTER
PROG.
R/W
Step
Used Parameters
Setpoint Value and Direction of
Rotation (oP.0)
In order to adjust the setpoint value via the motor potentiometer oP.0 (set value source)
must be adjusted accordingly.
Rotation
oP.0
Set Value
Keyboard/Bus
15
Motor potent.
Terminal strip
16
Motor potent.
±Motor potent.
17
Motor potent.
Motor Potentiometer/Target
(oP.31)
Apart from the setpoint value setting the motor potentiometer can be assigned to
further functions. For that the actual percentage (ru.34) is represented on a defined
parameter, the target parameter, and can change it. Possible target parameters are:
oP.31
Motor potentiometer / Target
0
no target parameter
1
dr.35 gearbox factor channel 1 (62,5%)
2
dr.36 gearbox factor channel 2 (62,5%)
(max. parameter value at ...% attained)
To prevent any dead travel in the motor potentiometer the maximum operating range
(oP.28) should be adjusted to the corresponding percentage.
ru.34
2022h
-
✔
-
100,00
100,00
0,01
0
-
oP.0
2100h
✔
✔
✔
0
26
1
1
Value 15, 16 o. 17
oP.26
211Ah
-
-
-
0
15
1
8
-
oP.27
211Bh
-
-
-
-100,00
100,00
0,01
0,00
-
oP.28
211Ch
-
-
-
-100,00
100,00
0,01
0,00
-
oP.29
211Dh
-
-
-
0
300,00 s
0,01s
131,00s
-
oP.30
211Eh
✔
-
✔
0
8
1
0
-
oP.31
211Fh
✔
-
✔
0
2
1
0
-
di.3
2903h
:
:
✔
-
✔
0
16
1
0
Adjust value 7, 8 o. 10
di.10
290Ah