![KEB COMBIVERT F4-C Applications Manual Download Page 160](http://html1.mh-extra.com/html/keb/combivert-f4-c/combivert-f4-c_applications-manual_3852415160.webp)
6
8
KEB COMBIVERT F4-C
4
Name: Basis
29.01.98
Functional Description
Parameter Sets
©
KEB Antriebstechnik, 1997
All Rights reserved
Chapter
Section
Page
Date
Picture 6.8.3.a
Principle of parameter set selection
Error message „nco“
If error message „nco“ is displayed, it may have following reasons:
Reason
Attempt to copy the default set (def) into
the active set
During initialization (init) the control
release was not dsabled.
Source and target set are identical.
The current set (A) is selected as target
set.
Remedy
Open the control release or activate
another parameter set.
Open control release or trigger error.
Change either source or target set.
Select valid value (0...7) as target set.
Adjustment of source and
target set via bus
(Fr.1 / Fr.9)
At bus operation two parameters are responsible for the copying of parameter sets.
Fr.9 defines the target set. Fr.1 defines the source parameter set and starts the copying
process. These parameters are not visible via keyboard.
6.8.3
Selection of Para-
meter Sets
Terminals
binary coded
Terminals
input coded
Fr.4 with
Keyboard / Bus
Set selection deactivated
always Set 0 activ
Fr.2
0
1
2
3
Aktual
Parameter set
Parameter set 0...7
Is
selected
Set
locked?
Fr.3 Parameter set lock
0..7 (Value 0..255)
no
yes
Error message
E.SEt
2
0
2
1
2
2
1
2
3
4
5
6
7
Set 0..7
Set 0..7
I1...ID (max.7)
I1 has priority
I1...ID (max.3)
I1 < I2 <....<ID