Password
Structure
The KEB COMBIVERT is provided with extensive password protection. The different
passwords are used to
- change the operating mode
- set a write protection
- activate the Service-Mode
- switch to the Drive-Mode
Depending on the actual operating mode the password can be entered in following
parameters
when the CP-Mode is active
when the applicatioan mode is active
The parameter value of the above parameters shows the actual password level.
Following indications are possible:
CP - read only
CP - on
CP - Service
Application
Drive-Mode
4.2.1
Password Levels
Only the Customer-parameter
group is visible, exept for CP.0 all
parameters are in the read-only
status (see Chapter 4.3).
Only the Customer-parameter
group is visible. All parameters can
be changed.
Like CP-on, but the parameter
identification is indicated according
to the original parameter (see
Chapter 4.3).
All application parameters are
visible and can be changed. The
CP-parameters are not visible.
The Drive-Mode is a special
operating mode, here the unit can
be put into operation via the
operator (see Chapter 4.4).