![KEB COMBIVERT F4-C Applications Manual Download Page 176](http://html1.mh-extra.com/html/keb/combivert-f4-c/combivert-f4-c_applications-manual_3852415176.webp)
6
9
KEB COMBIVERT F4-C
12
Name: Basis
29.01.98
Name: Basis
Chapter
Section
Page
Date
©
KEB Antriebstechnik, 1997
All Rights reserved
Functional Description
Special Functions
Param
.
Adr.
min
max
default
ENTER
PROG.
R/W
Step
Buffering of short-time Power
Failures
Parameter Setting
Remarks
Pn.17
199 (Auto)
automatic adaption to starting voltage even at mains
fluctuations
Pn.33
2 (Bit 0 +1)
starting voltage = 85 % of DC-link voltage during nor-
mal operation
Pn.41
199 (Auto)
setpoint value DC-link voltage = starting voltage
(Pn.17)
Pn.18
0 (Uzk-Mode)
DC-link voltage control activated
Emergency Stop with Braking
Module
Parameter Setting
Remarks
Pn.17
199 (Auto)
automatic adaption of starting voltage even at mains
fluctuations
Pn.33
2 (Bit 0 +1)
starting voltage = 85 % of DC-link voltage during nor-
mal operation
Pn.18
100%
DC-lnk voltage control deactivated; the drive is
decelerated as quickly as possible
Emergency Stop without
Braking Module
Parameter Setting
Remarks
Pn.17
199 (Auto)
automatic adaption of starting voltage even at mains
fluctuations
Pn.33
2 (Bit 0 +1)
starting voltage = 85 % of DC-link voltage during nor-
mal operation
Pn.18
0 (Uzk-Mode)
DC-link voltage control activated
Pn.42
> 199
adjustment of desired setpoint value
Used Parameters
Pn.17
2211h
✔
-
- 198, 199, 200
800 V
1
198 (off)
198:off; 199:auto
Pn.18
2212h
✔
-
-
0; 0,1
100 %
0,1
0
0: UZK-Mode
Pn.19
2213h
✔
-
-
0
409,5875 Hz
0,0125
0 Hz
-
Pn.33
2221h
✔
-
-
0
127
1
2
bitcodiert
Pn.34
2222h
✔
-
-
0
2000
1
512
-
Pn.36
2224h
✔
-
-
0
2000
1
50
-
Pn.37
2225h
✔
-
-
0
2000
1
50
-
Pn.38
2226h
✔
-
-
0
255 %
1 %
100 %
-
Pn.42
222Ah
✔
-
-
199; 200
800 V
1
199
199: auto
Pn.43
222Bh
✔
-
-
0
100,00 s
0,01 s
0 s
-