Bus-/DRIVECOM-Parameter
KEB COMBIVERT F4-C
Chapter
Section
Page
26.03.98
Date
Name:Basis
©
KEB Antriebstechnik, 1996
All Rights reserved
Adr.
min
max
default
Adr.
min
max
default
Adr.
min
max
default
Pr. 39 Percent reference value
0127h
0
32767
1
1500
1/min
Definition of the speed value that applies to Pr.38 as 100% value.
Pr. 40 Percent actual value
0128h
-200
200
0,61
-
%
Indication of the actual value in percent referred to Pr.39. 16383
∧
100% = Pr.39
Pr. 41 Percent reference variable
0129h
-200
200
0,61
-
%
Indication of the actual value at the output of the ramp generator in percent referred to Pr.39.
16383
∧
100% = Pr.39
Parameters Pr.10…Pr.27 are set-dependent. A change of parameters Pr.10…Pr.27
also causes a change of the oP-parameters!
If the oP-parameters are changed the values for the direction of rotation „forward“ are
accepted by the Pr-parameters!