3. Description of the tanning device
3.1 Standards
This tanning device is in conformity with performance standards 21 CFR 1040.20 and the standards for
electromagnetic compatibility (EMC):
EN55015; EN55014-1; EN55014-2; EN61000-3-2; EN61000-3-3; EN61000-3-12; EN62233; EN60601-1-2; EN61000-4-2; EN61000-4-4;
EN61000-4-5; EN61000-4-6
According to CISPR 11 the electromagnetic emission characteristic of this tanning device is classifi ed in Group1
and Class A.
The emission characteristics of this device make it suitable for use in industrial areas and hospitals (CISPR 11
class A). If it is used in a residential environment (for which CISPR 11 class B is normally required) this device
might not offer adequate protection to radio-frequency communication services. The studio operator might need
to take mitigation measures, such as relocating or re-orienting the equipment.
See EMC Tables according to 60601-1-2 : 2007
Table 1
Guidance and Manufacturer’s Declaration - Electromagnetic Emission
KBL Tower pureEnergy is intended for use in the electromagnetic environment specifi ed below. The studio
operator of KBL Tower pureEnergy should assure that it is used in such an environment.
Emission tests
Compliance
Electromagnetic environment - Guidance
RF emissions
according to CISPR 11
Group 1
KBL Tower pureEnergy uses RF energy exclusively for its
internal FUNCTION. Therefore, its HF emissions are very low
and not likely to cause any interference in nearby electronic
equipment.
RF emissions
according to CISPR 11
Class A
KBL Tower pureEnergy is intended for use in facilities other
than residential areas, and for facilities that are directly con-
nected to a public low-voltage supply system that also sup-
plies residential buildings.
Harmonics
according to IEC 61000-3-2
Class A
Voltage fl uctuations/
fl icker emissions
according to IEC 61000-3-3
Complies
Summary of Contents for Tower pureEnergy
Page 1: ...OPERATING INSTRUCTIONS TANNING DEVICE ...
Page 59: ...O p e r a t i n g I n s t r u c t i o n s KBL Tower pureEnergy 60 Remarks ...
Page 61: ...O p e r a t i n g I n s t r u c t i o n s KBL Tower pureEnergy 62 Remarks ...
Page 62: ...Ringstraße 24 26 56307 Dernbach Germany fon 49 0 26 89 94 26 0 fax 49 0 26 89 94 26 66 ...