O p e r a t i n g I n s t r u c t i o n s
|
KBL Tower pureEnergy
54
10. System messages
ERROR MESSAGES
Faults no. 07, 08, 12 and 13 do not occur with the KBL/5 processor due to its equipment and processor structure.
No.
Status message
KBL 4
Status message
KBL 5
Description
Remedy
01
Exhaust
air, Excess
temperature
bimetal!
Temp. Err.
Bi-metal switch triggers.
Check the air-intake/air-exhaust system
and the fan. Let the tanning system cool
down and acknowledge the message by
pressing the START button. If the fault
persists, contact your Customer Service.
02
Maximum
tanning time!
max. time
Incoming enabling signal from coin-box
system longer than approved, i.e. the
value specifi ed under “Maximum tanning
time” (voltage remains connected).
Disconnect the Tower from the coin-box
system.
03
Excess
temperature
sensor
> 66 °C
The sensor has measured the limit value
of 66 °C.
Check the air-intake/air-exhaust system
and the fan. Let the tanning system cool
down and acknowledge the message by
pressing the START button. If the fault
persists, contact your Customer Service.
04
High
temperature
sensor
> 62 °C
A temperature exceeding 62 °C is
measured for more than 3 minutes.
Check the air-intake/air-exhaust system
and the fan. Let the tanning system cool
down and acknowledge the message
by pressing START. If the fault persists,
contact your Customer Service.
05
1 temperature
sensor faulty!
1 sensor f.
One temperature sensor has not been
found by the control system.
Replace the temperature sensor in the
door (contact your Customer Service).
06
2 temperature
sensors faulty!
2 sensor f.
Both temperature sensors have not been
found by the control system. Ventilation
works at 100 % power.
Replace temperature sensors in the door
(contact your Customer Service).
07
Aqua low
The content of the aquaCool canister
is suffi cient for another 750 spraying
seconds (2.5 operating hours at a cycle
time = 1 minute).
Replace the empty aquaCool canister
with a full one. Do not replace aquaCool
with any other liquid. If the canister is not
empty, replace the liquid-level sensor
(contact your Customer Service).
08
Bus Error
I²C bus faulty.
Contact your Customer Service.
09
Error reading
measurand
measur. f.
Temperature values outside the range of
0 - 85 °C.
Replace the temperature sensor. If the
fault persists, replace the 1-wire-adaptor
board including bus cable (contact your
Customer Service).
11
Connection
1-Wire interface
faulty
1-Wire f.
No connection to 1-wire-adaptor (e.g.
cable break). Bus cable or 1-wire bus
adaptor defective.
Replace the bus cable. If the fault persists,
replace the 1-wire bus adaptor (contact
your Customer Service).
12
Aqua 0%
750 spraying seconds (2.5 operating
hours at a cycle time = 1 minute) have
expired.
Replace the empty aquaCool canister
with a full one. Do not replace aquaCool
with any other liquid. If the canister is not
empty, replace the liquid-level sensor
(contact your Customer Service).
13
Hardware
error
Main board defective.
Replace the main board (contact your
Customer Service).
Summary of Contents for Tower pureEnergy
Page 1: ...OPERATING INSTRUCTIONS TANNING DEVICE ...
Page 59: ...O p e r a t i n g I n s t r u c t i o n s KBL Tower pureEnergy 60 Remarks ...
Page 61: ...O p e r a t i n g I n s t r u c t i o n s KBL Tower pureEnergy 62 Remarks ...
Page 62: ...Ringstraße 24 26 56307 Dernbach Germany fon 49 0 26 89 94 26 0 fax 49 0 26 89 94 26 66 ...