O p e r a t i n g I n s t r u c t i o n s
|
KBL Tower pureEnergy
44
DISCONNECT MAINS VOLTAGE
DANGER
Live parts
Danger of life or fatal injury due to electric
shock when touching live parts.
• Switch neutral
• Secure against reconnection
• Check for neutrality
• Ground and short-circuit
• Cover or shield any adjacent live parts or
components
• Before carrying out any maintenance work, the
tanning device must be disconnected from the
mains voltage. That means that all live cables must
be switched off. Switching off the tanning device
alone is insuffi cient, as certain points may remain
energized. Therefore, switch off fuses before per-
forming any work and – if possible – remove them.
ADDITIONAL PROTECTIVE MEASURES
Accidental reactivation may result in serious acci-
dents. After deenergizing, immediately secure all
switches and fuses used for deenergizing against
being switched on again.
• Unscrew circuit breakers.
Where circuit breakers cannot be unscrewed, a strip
of adhesive tape can be applied over the actuation
lever with the wording:
DANGER - DO NOT SWITCH
A sign with the text:
WORK IN PROGRESS
Place: ..............................
Sign may only be removed by: ............................
must always and immediately be securely mounted.
• It is essential that you, the owner, and / or the stu-
dio operator check all components for signs of
wear that can occur during normal use.
• After completing the work, refi t all safety devices
(e.g. switches).
Summary of Contents for Tower pureEnergy
Page 1: ...OPERATING INSTRUCTIONS TANNING DEVICE ...
Page 59: ...O p e r a t i n g I n s t r u c t i o n s KBL Tower pureEnergy 60 Remarks ...
Page 61: ...O p e r a t i n g I n s t r u c t i o n s KBL Tower pureEnergy 62 Remarks ...
Page 62: ...Ringstraße 24 26 56307 Dernbach Germany fon 49 0 26 89 94 26 0 fax 49 0 26 89 94 26 66 ...