Mini Amazon III Series
14
Total Pipe
m
100
100
Length(Actual)
Outdoor unit up
Max. difference in
level
30m
30m
Outdoor unit down
20m
20m
Connection wiring
Power wiring
mm
2
3*6.0
3*6.0
Signal wiring
mm
2
3 core shielded
3 core shielded
wire x 0.75
wire x 0.75
Ambient temp
°C
Cooling: -5~55, Heating: -15~27
Notes:
1. The cooling conditions: indoor temp: 27°CDB (80.6°F), 19°CWB (66.2°F) outdoor temp: 35°CDB (95°F) equivalent pipe length: 5m drop
length: 0m.
2. The heating conditions: indoor temp: 20°CDB (68°F), 15°CWB (44.6°F) outdoor temp: 7°CDB (42.8°F) equivalent pipe length: 5m drop
length: 0m.
3. Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of *m(1m for 80/105 model, 1.2m
for 120~160 model). During actual operation, these values are normally somewhat higher as a result of ambient conditions.
4. The above data may be changed without notice for future improvement on quality and performance.
2 Dimensions
Figure 2-2.1: 80 model front view dimensions (unit: mm)
Figure 2-2.: 80 model top view dimensions (unit: mm)
Figure 2-2.3: 100/120 model front view Dimensions (unit: mm) Figure 2-2.4: 100/120 model front top Dimensions (unit: mm)
Summary of Contents for KMF-100 DVN4