Step 13. Powering the KT-300
_
_
_
_
_
Power the KT-300 controller
After you have completed all the necessary steps, you may power
the KT-300 controller.
How to:
1. Connect AC power
2. Connect the battery
Note: The KT-300 unit will not start on battery alone.
KT-300 FCC & IC Compliance Notice
This device complies with Part 15 of the FCC rules. Operation is
subject to the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must accept any
interference received including interference that may cause un-
desired operation. This class B digital apparatus meets all require-
ments of the Canadian Interference Causing Equipment Regula-
tions. The KT-300 is also compliant with EN55022: 1994, amend-
ment 1: 1995, Class B.
KT-300 CE Compliance Notice
This equipment has been tested and found to comply with the
limits to EN 50130-4 : 1995.
KT-300 UL Compliance Notice
In order to comply with UL listings, the following has to be
respected:
• Use of a UL listed computer
• Use of UL listed readers (Wiegand 26 and 34 bits, mag stripe
26 and 34 bits, have been tested and found to comply)
• Use of a tamper switch on every housing cabinet for the KT-
300
• Do not use a VC-485 (not UL listed)
• Do not use the SmartLink option (has not been investigated by
UL)
• Use a KT-LCD4501 module on each KT-300 controller
• Do not use a 220V transformer (not UL listed)
• Use only UL listed cables
• Use only UL listed adaptors
Note: Backup battery provides operation of up to 12 hours but
has been tested only 4 hours as per Section 33 of UL 294, fifth
edition.
Note: All circuits are power limited
Electrical Specifications
V O LTAG E O U TPUTS
M AX IM U M
C U R R EN T
A B S O LUTE
C O M B IN ED
M AX IM U M
Lo ck O utputs (1 2 V DC )
50 0 mA
(250 mA each)
1 .5 A
A uxiliary P ow er (12 V D C )
12 5 mA
Reader 5 V DC and 12 VD C
17 5 mA
C ombus
50 0 mA
Battery C harging (1 2V D C )
25 0 mA
O PEN C O LLECTO R O U TPU TS
M AX IM U M
C U R R EN T
LED (d oor 1 & 2)
25 mA (each)
Buzzer (Buz, d oor 1 & 2)
25 mA (each)
C ontrolled Relay 1 & 2 (RL1 & RL2)
25 mA (each)
Troubleshooting Communication Problems
Default Initialization:
The KT-300 default initialization is done at Kantech. The follow-
ing steps should only be done if :
(A) You changed the software (e.g.: you were using EntraPass,
then installed WinPass) and there’s no communication;
(B) The KT-300 was communicating via the RS-232 port and
you installed a VC-485 to communicate via the RS-485 port;
(C) You were using the KT-300 at a local site and now want to
configure it for remote operation.