4) By default, the reader type is Polaris 2 with Polaris cards, to
select a different reader, click on the requested reader type and
click on OK to continue the installation. Some readers offer the
possibility the 16-digit card driver format,
5) Select the COM port and baud rate and click on OK to continue
the installation. The default settings are COM Port 2 and 9600
baud rate.
Note: The KT-300 controller selects its communication speed
automatically. It can go up to 115,200 baud.
6) Once you have entered the baud rate, the system will display
the following question:
ExpressSetUp may be used at the initial installation or you may run
ExpressSetUp later. Whether it is the first time or not, the following
warning message will appear: This operation will modify all
controllers’ data. Do you want to continue?
Click on YES if this is a first installation.
Warning: If you are running ExpressSetUp once the system is
configured, the controller configurations including the Anti-
Passback option, REB-8, number of readers, reader types and
communication ports will be set to default. Other information
contained in the database (event tables) and user (cards) informa-
tion will not be modified.
ExpressSetUp associates the door contact for the first door of a
controller to input 1 and the second door contact to input 3. The
request-to-exit button or detector (REX) is associated to input 2
for door 1 and to input 4 for door 2. *
“S
EE
SECTION
11
IF
YOU
ARE
USING
KT-200
CONTROLLERS
”
After answering the question, the system will define the necessary
door controllers, the readers, the door contacts, the request-to-
exit detectors, etc. so you have a working system.
7) Once the system has finished the installation, the following
screen will be displayed:
8) Click on “serial number” button and enter the serial number of
the KT-300 controller (8 digits). The serial number allows
communication between controllers and the computer. Click
on OK to continue the installation.
Login the System
This section describes the login procedure.
1) Click on the login button
, the system will display:
2) Enter “WINPASS” as login name,
3) Enter “WINPASS” as password,
4) Click on the OK button.
Note: Remember to change this default password once the system