fiber-optic cable cleaning kit such as the Cletop - Cletop Reel-Type Cleaner – Part#
CLETOP-RL. Follow the directions for the cleaning kit you use.
Related
Documentation
Replacing an M7i FIC or PIC Cable on page 92
•
•
Troubleshooting the M7i FIC or PICs on page 80
Maintaining the M7i Routing Engine
Purpose
For optimum performance, verify the condition of the Routing Engine.
Action
Check the LEDs on the Routing Engine. The green LED labeled
ONLINE
lights steadily
when it is functioning normally. For more information about the LEDs, see “M7i Routing
Engine Description” on page 18.
•
•
Issue the CLI
show chassis routing-engine
command to check the status of the Routing
Engines:
user@host>
show chassis routing-engine
Routing Engine status:
Temperature 26 degrees C / 78 degrees F
DRAM 256 MB
Memory utilization 27 percent
CPU utilization:
User 0 percent
Background 0 percent
Kernel 4 percent
Interrupt 0 percent
Idle 96 percent
Model RE-5.0
Serial ID 1000392782
Start time 2003-06-11 11:39:32 PDT
Uptime 1 hour, 41 minutes, 51 seconds
Load averages: 1 minute 5 minute 15 minute
0.00 0.03 0.05
For further description of the output from the command, see the
Junos OS System Basics
and Services Command Reference
.
Related
Documentation
Replacing the M7i Routing Engine on page 97
•
•
Routing Engine Interface Cable and Wire Specifications for the M7i Router on page 179
Maintaining the M7i Power Supplies
Purpose
For optimum router performance, verify the condition of the power supplies.