To ground a router, connect a grounding cable to earth ground and then attach it to the
chassis grounding point on the rear of the chassis.
Table 21 on page 167 summarizes the specifications for the groundingcable, which you
must supply.
Table 21: Grounding Cable Specifications
Maximum
Equal
Length
Quantity and Specification
None
One 14-AWG (2.08 mm
2
) single-strand-count wire cable
Figure 61 on page 168 shows the location of the grounding point on the upper left side of
the M7i router above the power supplies.
CAUTION:
Before router installation begins, a licensed electrician must attach
a cable lug to the grounding cable that you supply. A cable with an incorrectly
attached lug can damage the router.
167
Copyright © 2010, Juniper Networks, Inc.
Appendix D: Power Guidelines, Requirements, and Specifications for the M7i Router