To remove a FIC or PIC cable:
1.
If the interface connects to fiber-optic cable, have ready a rubber safety cap for each
cable you are removing.
2.
If removing all cables connected to the interface, press and hold the PIC offline button
on the FIC until its failure indicator LED lights, which usually takes about 5 seconds.
The failure LED is usually red; for more information, see the
M7i Multiservice Edge
Router PIC Guide
.
3.
Unplug the cable from the cable connector port. If the interface uses fiber-optic cable,
immediately cover each transceiver and the end of each cable with a rubber safety
cap.
4.
Arrange the cable to prevent it from dislodging or developing stress points. Secure
the cable so that it is not supporting its own weight as it hangs to the floor. Place
excess cable out of the way in a neatly coiled loop. Placing fasteners on the loop helps
to maintain its shape.
Installing an M7i FIC or PIC Cable
WARNING:
Do not look directly into transceivers or into the ends of fiber-optic
cables connected to a transceiver. Fiber-optic transceivers emit laser light
that can damage your eyes.
CAUTION:
When handling fiber-optic transceivers and fiber-optic cable, observe the
following precautions:
•
Do not leave a fiber-optic transceiver uncovered except when inserting or
removing cable. The safety cap keeps the port clean and prevents
accidental exposure to laser light.
•
Do not bend fiber-optic cable beyond its minimum bend radius. An arc
smaller than a few inches in diameter can damage the cable and cause
problems that are difficult to diagnose.
•
Do not let fiber-optic cable hang free from the connector. Do not allow
fastened loops of cable to dangle, which stresses the cable at the fastening
point.
To install a PIC cable (see Figure 36 on page 94):
1.
Have ready a length of the type of cable used by the interface, as specified in “FIC
Specifications for the M7i Router” on page 173.
2.
If the interface cable connector port is covered by a rubber safety plug, remove the
plug.
3.
Insert the cable connector into the cable connector port on the interface faceplate.
93
Copyright © 2010, Juniper Networks, Inc.
Chapter 15: Replacing M7i Hardware Components
All manuals and user guides at all-guides.com