KE-2050/KE-2060, KE-2050R/2055R/KE-2060R Maintenance Manual
13-1
DANGER
To prevent any trouble caused by accidental machine start, always
shut-down the power before starting the maintenance and
adjustment work.
[13] OTHER UNITS
13-1. Replacing the CRT (Vision Monitor)
(1) Disconnect the monitor power cable
and detach the vision monitor.
Vision monitor
(2) Disconnect the image monitor cable
from the rear of the monitor head.
(3) Lower the hook on the base to slide
the lower portion of the head toward
the machine front. Raise the head to
detach the monitor.
(4) Reassemble the components in the
reverse order of disassembly.
Figure 13-1-1
画像モニタケーブル
つまみ
台座
頭部
Image monitor
cable
Hook
Base
Head
Figure 13-1-2
Rev. 2.00