KE-2050/KE-2060, KE-2050R/2055R/KE-2060R Maintenance
Manual
15-8
15-5-2. Mounting the B/U Pin Detection Sensor (Bundling the Cables)
L- and E-Size
HX003140000
スパイラルチューブ
0.5 m
レールプレート RL
ベースフレーム
Y軸フレーム R/L
レールプレートRR
HX003140000
スパイラルチューブ
0.5 m
束線バンド
(基板へ)
ベースバー
束線バンド
HX003140000
Spiral tube
0.5 m
Tie-up band
Rail plate RL
(To circuit board)
Base frame
Y-axis frame R/L
Base bar
HX003140000
Spiral tube
0.5 m
Tie-up band
Rail plate RR
Fix the cable with the tie-up band put
in holes in the rail plates RR and RL.
Wind the spiral tube (HX003140000) at the
top of the cable fixed by the tie-up band.
Figure 15-5-2-1
For part where the solenoid valve is mounted, pass the cable under the Y-axis frame once and run
it upward through the gap between the Y-axis frame and base bar in order to prevent the cable
from being caught in.
Change the rail width between the maximum and minimum levels to check that the cable does not
interfere with other objects, such as solenoid valve or rail support.