KE-2050/KE-2060, KE-2050R/2055R/KE-2060R Maintenance Manual
1-34
Rev. 2.00
Figure 1-8-8-2 KE-2060/2060R
OCCA (L), OCCA (R)
Cable
Tie-up band
OCCV (L), OCCV (R)
CN803
CN804
CN806
CN805
CN802
CN801
CN808
X
CN84
9
Fix only on the
head plate side.
To FMLA
Clamp to the
screw-fastened fixture base
tightened together with the
head handle.
Also clamp the magnescale
and MNLA cables together
(the left case only).
Plug the Z and
θ
connectors of the motor starting from the
left in the order of CN209, CN210, ..., CN218. (Plug into
the connector bracket 60 from bottom to top.)
To FMLA Z sensor
To MNLA Z sensor
See the figure
below.
See the figure
below.
To the OCC relay board.
Clamp the cables on the
board in a bundle within
50mm of the connector.
Clamp the cables on the
board in a bundle within
50mm of the connector.
Cables to be clamped to
the camera bracket U:
•
Magnescale
•
OCC light, camera
•
MNLA
The CN849
connector shall not
protrude in the left of
the FC guide.
Figure 1-8-8-2 KE-2060/2060R
(2) Clamp the cables following the figure above. Use the large tie-up band for the FC guide, and
the small tie-up band for other parts. When clamping, take care not to apply undue bending nor
load to the cables. If some part is covered with a cable protective sheet, tie up the cables within
the width of the sheet.