2-3-2. FMLA Head
(1) Remove the peripheral components
following the steps (1), (2), (4) and (7) in
the section 2-1-2.
(2) Remove the Z-sensor base IC mounting
screws
19
(2 pcs.) and detach the
Z-sensor base IC downward.
(3) Cut the tie-up band to replace the
Z-sensor.
(4) Reassemble the components in the
reverse order of assembly.
⑲
(5) Check following the procedure below and
make adjustments if necessary.