2.2 Prearrangement for electrical connections, air inlets and stove positioning
163
163
1325
1400
150
350
120
450
330
Ø180
To enable maintenance of the pellet burner, the electronic control and the Caldo Control system, ensure sufficient free space on the
left and right of the stove for opening the side doors fully.
The minimum clearances to be respected are given in the following
figures
. The minimum clearance between the side of the stove and adjacent walls must be respected on both sides. The floor have
to be strong enought to hold the machine in case it is not fitting the requirements than take necessary actions (ex. charge distribution
plate). The machine has to be installed to be easely cleaned, smoking pipes and chimney easely reached and cleaned too please install
accordingly. The expansion vase has to be correctly calculated therefore check if the one available is big enought for your installation.
Omnipolar
switch
220V 50Hz
power supply
All measurements are in millimetres (mm)
Room temperature probe
or room thermostat (to
be placed away from the
stove)
Prearrangement
of hot air ducting
pipes
Combustion
fan
connection pipe
(max. length 50 cm)
Compulsory
outside
air inlet
Electrical connections must be carried out by skilled personnel according to the regulations in force (CE 2006/95 and 2004/108).