16
1.7 New-generation simplified electronic controller
1.7.10 Eliminating problems regarding combustion
If the pellets do not burn well after having installed the stove correctly and thoroughly cleaned the burn pot, boiler body, flue and
outside air inlets (this could be due to the use of pellets having different characteristics from those with which the stove was tested,
therefore it is advisable to only use pellets of the recommended type), the pellet feed and combustion air can be adjusted to obtain
the correct combustion ratio and optimum efficiency.
The various steps to be carried out are given below (the fireplace must be set to medium power).
BUTTONS
modify
+
-
1.7.11 Electronic component test
Switch off the electronic controller by pressing
OFF
.
Press the button
TEST
, holding it down for a few seconds; the electronic controller will activate the selected part.
Check the part being tested.
To skip a part test, press
ESC
.
Press
OK
if the part functions; the electronic controller automatically goes to the next part.
BUTTONS
esc
ok
test
OFF
off
NOTE!
If any of the parts tested does not function, contact the Technical Assistance Service.
• Adjusting pellet quantity
To set the pellet quantity, when the operation status screen is
displayed, press
MODIFY
repeatedly until
“SET PELLET %”
appears
.
Increase or reduce within the range -10% to +20% with the
buttons .
• Adjusting combustion air
To set the combustion air, when the operation status screen
is displayed, press
MODIFY
repeatedly until
“SET COMB. AIR
%” appears
.
Increase or reduce within the range -10% to +20% with the
buttons
.
Summary of Contents for FOGHEA
Page 46: ...46 Notes...
Page 47: ...47 Notes...