SECURITY AND ARMING
Setting
Default
Description
Keyfob Disarming
Enabled
When Disabled, a Keyfob will not be able to disarm the panel
Engineer’s Reset
Disabled
If a confirmed alarm occurs on a burglary zone, the system is locked out after disarming until a 5
digit reset code provided by the installer is entered in.
Allow Master Code to Access
Security and Arming
Disabled
Allow the master code to access these features and settings.
NOTE:
this option shall be disabled for UL/cUL. This option shall be enabled for UL Commercial Burg installations.
Normal Entry Delay
30 Secs
How much time users have to enter their code after opening a door (30-240secs). With SIA
limits disabled the minimum time can be set to 5 secs.
NOTE:
For UL Commercial Burg (UL2610) maximum entry delay should not exceed 60s
Normal Exit Delay
60 Secs
How much time users have to exit the location before the panel arms itself (30-254secs). With
SIA limits disabled the minimum time can be set to 5 secs. Door/Window group 10 follows the
“Normal Exit Delay”
NOTE:
For UL Commercial Burg (UL2610) maximum exit delay should not exceed 60s
Long Entry Delay
100 Secs
A second separate entry delay that can be used on a sensor needing more time when tripped
(45-240secs). With SIA limits disabled the minimum time can be set to 5 secs
Long Exit Delay
120 Secs
A second separate exit delay that can be used on a sensor needing more time when tripped
(45-254secs). With SIA limits disabled the minimum time can be set to 5 secs. Door/Window
group 12 follows the “Long Exit Delay”
QOLSYS CONFIDENTIAL AND PROPRIETARY
PAGE OF
45
178
PROGRAMMING
Summary of Contents for IQ Panel 4
Page 8: ...INSTALLING THE PANEL ...
Page 15: ...USER INTERFACE ...
Page 19: ...PROGRAMMING ...
Page 56: ...SECURITY SENSORS ...
Page 89: ...WI FI DEVICES ...
Page 96: ...Z WAVE DEVICES ...
Page 107: ...BLUETOOTH DEVICES ...
Page 114: ...SYSTEM TESTS ...
Page 137: ...CUSTOMIZATION ...
Page 146: ...MAINTENANCE ...
Page 153: ...TROUBLESHOOTING ...
Page 162: ...LEGAL ...
Page 173: ...SPECIFICATIONS ...