PROGRAMMING
INSTALLER/DEALER SETTINGS
* Additional options available
only through the Dealer Code.
FIND IT
INSTALLER/DEALER
SETTINGS
Swipe down
for access
INSTALLATION
SETTINGS
ADVANCED SETTINGS
ENTER CODE (1111, 2222)
Setting
Default
Description
Account Number
blank
Security provider account number (up to 10 characters)
Power Management
Enabled
An energy-saving function when running on battery power only
SIA Power Restoration
Disabled
Turn on or off sensor hold for 60 seconds during power restore
ULC Commercial Power
Restoration
Disabled
When enabled, ignore all sensor activity for 120 seconds after
power restoration
Loss of Supervisory Signals
for Emergency Sensors
4
Select the length in hours (4, 12, 24) before reporting a loss of
supervision on life safety devices.
NOTE:
For UL/cUL Resi Fire and UL Commercial Burg (UL2610) the wireless supervision
window for Emergency sensors (Smoke, Heat & CO Detectors) shall be set to 4h
Loss of Supervisory Signals
for PowerG Emergency
Sensors
4
Select the length of time (20, 30 min, 1, 2, 4, 12, 18 hours) before
reporting a loss of supervision on PowerG life safety devices.
NOTE:
For UL/cUL Resi Fire and UL Commercial Burg (UL2610) the wireless supervision
window for Emergency sensors (Smoke, Heat & CO Detectors) shall be set to 2h
Installer/Dealer Settings
Change panel settings like supervisory times, power and cell loss timeout and
SIA settings.
Summary of Contents for IQ Panel 4
Page 8: ...INSTALLING THE PANEL ...
Page 15: ...USER INTERFACE ...
Page 19: ...PROGRAMMING ...
Page 56: ...SECURITY SENSORS ...
Page 89: ...WI FI DEVICES ...
Page 96: ...Z WAVE DEVICES ...
Page 107: ...BLUETOOTH DEVICES ...
Page 114: ...SYSTEM TESTS ...
Page 137: ...CUSTOMIZATION ...
Page 146: ...MAINTENANCE ...
Page 153: ...TROUBLESHOOTING ...
Page 162: ...LEGAL ...
Page 173: ...SPECIFICATIONS ...