SIREN AND ALARMS
Setting
Default
Description
PowerG Smoke Detector Siren
Fire Alarms Only
When set to “Fire Alarms Only”, PowerG Smoke Detectors that are learned into the
system will only sound during fire alarm events. When set to “All Alarms”, PowerG Smoke
Detectors will act as additional wireless sirens and will sound during all alarm events.
Police Panic
Enabled
Allows Police Panic to be enabled or disabled.
Fire Panic
Enabled
Allows Fire Panic to be enabled or disabled.
Auxiliary Panic
Enabled
Allows Auxiliary Panic to be enabled or disabled.
Audible Siren for Wireless
Supervisory Failures
Disabled
When this setting is enabled and the system is armed, supervisory failures for non-
emergency sensors are treated the same as a tamper and cause an alarm to be generated.
Allow Master Code To Access Siren
and Alarms
Disabled
Allow the master code to access these features and settings.
NOTE
: not allowed for UL/cUL.
QOLSYS CONFIDENTIAL AND PROPRIETARY