SECURITY AND ARMING
FIND IT
SECURITY AND
ARMING
Swipe down
for access
INSTALLATION
SETTINGS
ADVANCED SETTINGS
ENTER CODE (1111, 2222)
Setting
Default
Description
Dealer Code*
2222
Code to access all options
Installer Code
1111
Code to access installer options only
Swinger Shutdown
Enabled
Determines whether the panel allows the same sensor to trip the
alarm more than once (enabled), or not (disabled)
Swinger Shutdown
Count
1
Determines the number of times the same sensor is allowed to trip the
alarm during the same arming period (1-6). Swinger Shutdown must
be enabled in order for this setting to work
Panel Tamper
Enabled
This setting enables or disables the Panel Tamper switch on the back of
the panel.
NOTE
: for UL/cUL this setting shall be Enabled
Screen Lock
Disabled
When enabled, a screen lock page will appear. Screen lock restricts
access to the panel based on valid user codes.
NOTE
: This setting is required
and is automatically enabled when Partitions are enabled. It is also enabled for "En Grade 2”
Security and Arming
Change arming settings, entry and exit delays, enable Duress Authentication
and more.
* Additional options available
only through the Dealer Code.
QOLSYS CONFIDENTIAL AND PROPRIETARY
PAGE OF
43
178
PROGRAMMING
Summary of Contents for IQ Panel 4
Page 8: ...INSTALLING THE PANEL ...
Page 15: ...USER INTERFACE ...
Page 19: ...PROGRAMMING ...
Page 56: ...SECURITY SENSORS ...
Page 89: ...WI FI DEVICES ...
Page 96: ...Z WAVE DEVICES ...
Page 107: ...BLUETOOTH DEVICES ...
Page 114: ...SYSTEM TESTS ...
Page 137: ...CUSTOMIZATION ...
Page 146: ...MAINTENANCE ...
Page 153: ...TROUBLESHOOTING ...
Page 162: ...LEGAL ...
Page 173: ...SPECIFICATIONS ...