505429-JTG-L-0512
Johnson Controls Unitary Products
25
115°F
125°F
3750
77
153.8
15.8
77.6
61.4
45.3
-
-
-
147.7
17.5
76.3
60.1
44.0
-
-
-
72
142.2
15.5
101.0
84.8
68.7
52.5
-
-
136.2
17.2
99.2
83.0
66.9
50.8
-
-
67
130.5
15.1
124.4
108.2
92.0
75.9
59.7
-
124.7
16.8
122.1
105.9
89.8
73.7
57.6
-
62
128.2
15.1
128.2
128.2
120.4
104.2
88.0
71.9
125.8
16.8
125.8
125.8
118.7
102.6
86.5
70.4
57
131.2
15.2
131.2
131.2
115.2
99.0
82.8
66.7
127.8
17.0
127.8
127.8
111.0
94.9
78.7
62.6
4375
77
155.5
15.7
92.3
67.0
48.4
-
-
-
148.1
17.3
93.2
65.4
46.8
-
-
-
72
143.8
15.3
110.6
92.0
73.4
54.7
-
-
136.5
17.0
108.4
89.8
71.2
52.5
-
-
67
132.0
15.0
128.9
117.0
98.3
79.7
61.1
-
125.0
16.6
123.7
114.2
95.5
76.9
58.3
-
62
129.7
15.0
129.7
129.7
128.6
110.0
91.3
72.7
126.2
16.7
126.2
126.2
126.2
107.8
89.1
70.4
57
132.7
15.1
132.7
132.7
123.1
104.4
85.8
67.2
128.1
16.8
128.1
128.1
118.0
99.7
80.8
62.1
5000
77
157.3
15.5
107.1
72.6
51.5
-
-
-
148.4
17.1
110.2
70.7
49.6
-
-
-
72
145.4
15.2
120.3
99.2
78.1
57.0
-
-
136.8
16.8
117.7
96.6
75.4
54.3
-
-
67
133.5
14.9
133.5
125.8
104.7
83.6
62.5
-
125.2
16.4
125.2
122.4
101.3
80.1
59.0
-
62
131.1
14.9
131.1
131.1
136.9
115.8
94.7
73.6
126.6
16.5
126.6
126.6
126.6
113.1
91.6
70.5
57
134.2
15.0
134.2
134.2
131.0
109.9
88.8
67.7
128.5
16.6
128.5
128.5
125.1
104.5
82.8
61.7
5625
72
149.5
15.4
130.6
107.6
84.7
61.7
-
-
141.3
17.0
128.2
105.2
82.3
59.3
-
-
67
137.3
15.1
137.3
133.4
113.5
90.6
67.6
-
129.3
16.6
129.3
128.8
110.4
87.5
64.5
-
62
134.8
15.1
134.8
134.8
137.7
114.7
91.8
68.8
130.7
16.7
130.7
130.7
130.7
111.5
88.4
65.4
57
138.0
15.2
138.0
138.0
136.4
113.4
90.5
67.5
132.6
16.8
132.6
132.6
130.9
108.2
84.9
62.0
6250
72
153.6
15.6
140.9
116.1
91.3
66.5
-
-
145.7
17.2
138.7
113.9
89.1
64.3
-
-
67
141.0
15.3
141.0
141.0
122.4
97.6
72.8
-
133.4
16.8
133.4
133.4
119.6
94.8
69.9
-
62
138.5
15.3
138.5
138.5
138.5
113.7
88.9
64.1
134.7
16.9
134.7
134.7
134.7
109.9
85.1
60.2
57
141.8
15.4
141.8
141.8
141.8
117.0
92.2
67.4
136.7
17.1
136.7
136.7
136.7
111.9
87.1
62.3
1
These capacities are gross ratings. For net capacity, deduct supply air blower motor, MBh. Example: Refer to the appropriate Blower
Performance Table for the BHP of the supply air blower motor, MBh = 3.415 x kW and kW = BHP x 0.746
nameplate rated motor
efficiency.
2
These ratings include the condenser fan motors and the compressor motors but not the supply air blower motor.
J12YC/J15NC
(Continued)
Air on
Evaporator Coil
Temperature of Air on Condenser Coil
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
CFM
WB
(°F)
Return Dry Bulb (°F)
Return Dry Bulb (°F)
90
85
80
75
70
65
90
85
80
75
70
65
Summary of Contents for Duct R-410A
Page 81: ...505429 JTG L 0512 Johnson Controls Unitary Products 81 Typical J10 12YC Wiring Diagram ...
Page 82: ...505429 JTG L 0512 82 Johnson Controls Unitary Products Typical J10 12YD Wiring Diagram ...
Page 83: ...505429 JTG L 0512 Johnson Controls Unitary Products 83 Typical J15YC Wiring Diagram ...
Page 84: ...505429 JTG L 0512 84 Johnson Controls Unitary Products Typical J20YC Wiring Diagram ...
Page 85: ...505429 JTG L 0512 Johnson Controls Unitary Products 85 Typical J25YC Wiring Diagram ...
Page 86: ...505429 JTG L 0512 86 Johnson Controls Unitary Products Typical J15 20YD Wiring Diagram ...
Page 88: ...505429 JTG L 0512 88 Johnson Controls Unitary Products Typical J10PC Wiring Diagram ...
Page 89: ...505429 JTG L 0512 Johnson Controls Unitary Products 89 Typical J15 20PC Wiring Diagram ...
Page 90: ...505429 JTG L 0512 90 Johnson Controls Unitary Products Typical J15 20PD Wiring Diagram ...
Page 95: ...505429 JTG L 0512 Johnson Controls Unitary Products 95 Typical J25NC Wiring Diagram ...