505429-JTG-L-0512
Johnson Controls Unitary Products
21
115°F
125°F
3000
77
117.5
12.0
63.4
50.4
37.4
-
-
-
108.0
13.2
60.3
47.2
34.1
-
-
-
72
109.1
11.9
81.0
68.0
55.0
41.9
-
-
101.2
13.2
78.4
65.3
52.2
39.1
-
-
67
100.8
11.9
98.6
85.6
72.6
59.5
46.5
-
94.3
13.1
94.3
83.4
70.3
57.2
44.1
-
62
94.0
11.8
94.0
94.0
89.4
76.4
63.4
50.4
87.2
13.0
87.2
87.2
85.1
72.0
59.0
45.9
57
94.0
11.8
94.0
94.0
84.7
71.7
58.7
45.7
87.8
13.1
87.8
87.8
77.8
64.7
51.7
38.6
3500
77
124.2
12.0
74.4
55.8
41.1
-
-
-
115.1
13.2
73.6
53.0
38.1
-
-
-
72
115.4
11.9
89.9
75.2
60.4
45.7
-
-
107.7
13.2
87.9
73.1
58.2
43.4
-
-
67
106.6
11.9
105.5
94.6
79.8
65.1
50.3
-
100.4
13.1
100.4
93.2
78.3
63.5
48.6
-
62
99.4
11.8
99.4
99.4
98.4
83.6
68.9
54.1
92.8
13.0
92.8
92.8
92.8
80.4
65.2
50.3
57
99.4
11.8
99.4
99.4
93.2
78.5
63.7
49.0
93.5
13.1
93.5
93.5
86.9
72.4
57.2
42.3
4000
77
131.0
12.0
85.5
61.3
44.8
-
-
-
122.1
13.2
86.9
58.7
42.1
-
-
-
72
121.7
11.9
98.9
82.4
65.9
49.5
-
-
114.3
13.2
97.5
80.8
64.2
47.6
-
-
67
112.3
11.9
112.3
103.5
87.1
70.6
54.1
-
106.5
13.1
106.5
103.0
86.3
69.7
53.1
-
62
104.8
11.8
104.8
104.8
107.3
90.8
74.4
57.9
98.5
13.1
98.5
98.5
98.5
88.7
71.4
54.8
57
104.8
11.8
104.8
104.8
101.7
85.2
68.7
52.2
99.2
13.1
99.2
99.2
95.9
80.1
62.7
46.0
4500
72
124.7
11.9
107.6
89.3
71.0
52.8
-
-
116.1
13.2
106.1
87.5
68.9
50.3
-
-
67
115.2
11.9
115.2
110.8
93.8
75.5
57.2
-
108.2
13.1
108.2
108.2
92.6
74.0
55.4
-
62
107.4
11.8
107.4
107.4
108.7
90.4
72.1
53.8
100.0
13.1
100.0
100.0
100.0
84.9
65.9
47.3
57
107.4
11.8
107.4
107.4
105.9
87.6
69.3
51.0
100.7
13.1
100.7
100.7
99.1
80.9
61.9
43.3
5000
72
127.8
12.0
116.3
96.2
76.1
56.1
-
-
117.9
13.2
114.7
94.1
73.6
53.0
-
-
67
118.0
11.9
118.0
118.0
100.5
80.4
60.4
-
109.9
13.1
109.9
109.9
98.9
78.4
57.8
-
62
110.1
11.8
110.1
110.1
110.1
90.0
69.9
49.8
101.6
13.0
101.6
101.6
101.6
81.0
60.4
39.9
57
110.1
11.9
110.1
110.1
110.1
90.0
69.9
49.8
102.3
13.1
102.3
102.3
102.3
81.7
61.2
40.6
1
These capacities are gross ratings. For net capacity, deduct supply air blower motor, MBh. Example: Refer to the appropriate Blower
Performance Table for the BHP of the supply air blower motor, MBh = 3.415 x kW and kW = BHP x 0.746
nameplate rated motor
efficiency.
2
These ratings include the condenser fan motors and the compressor motors but not the supply air blower motor.
J10YC/J10NC
(Continued)
Air on
Evaporator Coil
Temperature of Air on Condenser Coil
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
CFM
WB
(°F)
Return Dry Bulb (°F)
Return Dry Bulb (°F)
90
85
80
75
70
65
90
85
80
75
70
65
Summary of Contents for Duct R-410A
Page 81: ...505429 JTG L 0512 Johnson Controls Unitary Products 81 Typical J10 12YC Wiring Diagram ...
Page 82: ...505429 JTG L 0512 82 Johnson Controls Unitary Products Typical J10 12YD Wiring Diagram ...
Page 83: ...505429 JTG L 0512 Johnson Controls Unitary Products 83 Typical J15YC Wiring Diagram ...
Page 84: ...505429 JTG L 0512 84 Johnson Controls Unitary Products Typical J20YC Wiring Diagram ...
Page 85: ...505429 JTG L 0512 Johnson Controls Unitary Products 85 Typical J25YC Wiring Diagram ...
Page 86: ...505429 JTG L 0512 86 Johnson Controls Unitary Products Typical J15 20YD Wiring Diagram ...
Page 88: ...505429 JTG L 0512 88 Johnson Controls Unitary Products Typical J10PC Wiring Diagram ...
Page 89: ...505429 JTG L 0512 Johnson Controls Unitary Products 89 Typical J15 20PC Wiring Diagram ...
Page 90: ...505429 JTG L 0512 90 Johnson Controls Unitary Products Typical J15 20PD Wiring Diagram ...
Page 95: ...505429 JTG L 0512 Johnson Controls Unitary Products 95 Typical J25NC Wiring Diagram ...