505429-JTG-L-0512
Johnson Controls Unitary Products
41
115°F
125°F
6000
77
244.4
23.4
120.7
96.0
71.4
-
-
-
229.9
25.9
117.5
92.5
67.5
-
-
-
72
226.2
22.8
156.5
131.9
107.2
82.6
-
-
212.8
25.1
153.2
128.2
103.2
78.1
-
-
67
208.0
22.1
192.4
167.7
143.1
118.5
93.8
-
195.7
24.3
188.9
163.9
138.9
113.8
88.8
-
62
192.2
21.6
192.2
192.2
178.1
153.5
128.8
104.2
179.4
23.8
179.4
179.4
173.7
148.6
123.6
98.6
57
194.4
21.8
194.4
194.4
174.8
150.2
125.5
100.9
184.6
23.9
184.6
184.6
162.9
137.9
112.9
87.8
7000
77
250.0
23.5
136.5
104.5
76.9
-
-
-
235.5
25.9
135.8
101.0
72.8
-
-
-
72
231.4
22.8
170.8
143.1
115.5
87.9
-
-
218.0
25.1
167.7
139.5
111.3
83.1
-
-
67
212.8
22.1
205.0
181.7
154.1
126.5
98.9
-
200.5
24.3
199.6
178.0
149.8
121.6
93.4
-
62
196.7
21.7
196.7
196.7
191.8
164.2
136.5
108.9
183.8
23.8
183.8
183.8
183.8
159.9
130.9
102.7
57
198.9
21.8
198.9
198.9
188.3
160.6
133.0
105.4
189.1
24.0
189.1
189.1
175.8
148.8
119.4
91.2
8000
77
255.7
23.5
152.4
113.0
82.4
-
-
-
241.1
25.9
154.0
109.5
78.1
-
-
-
72
236.6
22.8
185.0
154.4
123.7
93.1
-
-
223.2
25.1
182.1
150.8
119.4
88.0
-
-
67
217.6
22.2
217.6
195.7
165.1
134.5
103.9
-
205.3
24.3
205.3
192.1
160.7
129.3
97.9
-
62
201.1
21.7
201.1
201.1
205.5
174.9
144.3
113.6
188.2
23.9
188.2
188.2
188.2
171.2
138.2
106.9
57
203.3
21.8
203.3
203.3
201.7
171.1
140.5
109.8
193.6
24.0
193.6
193.6
188.6
159.7
125.9
94.5
9000
72
241.9
23.0
195.9
162.8
129.7
96.5
-
-
228.6
25.4
193.3
159.5
125.8
92.0
-
-
67
222.4
22.3
222.4
206.1
173.0
139.9
106.8
-
210.3
24.6
210.3
203.0
169.3
135.5
101.7
-
62
205.6
21.9
205.6
205.6
207.8
174.6
141.5
108.4
192.7
24.1
192.7
192.7
192.7
167.4
132.8
99.0
57
207.9
22.0
207.9
207.9
207.0
173.9
140.8
107.7
198.3
24.2
198.3
198.3
195.8
163.2
128.2
94.4
10000
72
247.2
23.2
206.8
171.2
135.6
100.0
-
-
233.9
25.6
204.5
168.3
132.1
95.9
-
-
67
227.3
22.5
227.3
216.5
180.9
145.3
109.7
-
215.2
24.8
215.2
214.0
177.8
141.6
105.4
-
62
210.0
22.0
210.0
210.0
210.0
174.4
138.8
103.2
197.3
24.3
197.3
197.3
197.3
163.5
127.4
91.2
57
212.4
22.2
212.4
212.4
212.4
176.8
141.2
105.6
202.9
24.5
202.9
202.9
202.9
166.7
130.5
94.3
1
These capacities are gross ratings. For net capacity, deduct supply air blower motor, MBh. Example: Refer to the appropriate Blower
Performance Table for the BHP of the supply air blower motor, MBh = 3.415 x kW and kW = BHP x 0.746
nameplate rated motor
efficiency.
2
These ratings include the condenser fan motors and the compressor motors but not the supply air blower motor.
J20YC/J20NC
(Continued)
Air on
Evaporator Coil
Temperature of Air on Condenser Coil
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
CFM
WB
(°F)
Return Dry Bulb (°F)
Return Dry Bulb (°F)
90
85
80
75
70
65
90
85
80
75
70
65
Summary of Contents for Duct R-410A
Page 81: ...505429 JTG L 0512 Johnson Controls Unitary Products 81 Typical J10 12YC Wiring Diagram ...
Page 82: ...505429 JTG L 0512 82 Johnson Controls Unitary Products Typical J10 12YD Wiring Diagram ...
Page 83: ...505429 JTG L 0512 Johnson Controls Unitary Products 83 Typical J15YC Wiring Diagram ...
Page 84: ...505429 JTG L 0512 84 Johnson Controls Unitary Products Typical J20YC Wiring Diagram ...
Page 85: ...505429 JTG L 0512 Johnson Controls Unitary Products 85 Typical J25YC Wiring Diagram ...
Page 86: ...505429 JTG L 0512 86 Johnson Controls Unitary Products Typical J15 20YD Wiring Diagram ...
Page 88: ...505429 JTG L 0512 88 Johnson Controls Unitary Products Typical J10PC Wiring Diagram ...
Page 89: ...505429 JTG L 0512 Johnson Controls Unitary Products 89 Typical J15 20PC Wiring Diagram ...
Page 90: ...505429 JTG L 0512 90 Johnson Controls Unitary Products Typical J15 20PD Wiring Diagram ...
Page 95: ...505429 JTG L 0512 Johnson Controls Unitary Products 95 Typical J25NC Wiring Diagram ...