505429-JTG-L-0512
58
Johnson Controls Unitary Products
115°F
125°F
6000
77
244.4
23.6
120.7
96.0
71.4
-
-
-
224.0
25.9
115.4
90.7
65.9
-
-
-
72
222.6
23.2
155.5
130.8
106.2
81.5
-
-
205.1
25.5
150.0
125.3
100.6
75.8
-
-
67
200.8
22.8
190.3
165.6
140.9
116.3
91.6
-
186.2
25.1
184.7
159.9
135.2
110.5
85.7
-
62
190.4
22.5
190.4
190.4
177.2
152.5
127.8
103.2
177.6
24.8
177.6
177.6
171.3
146.5
121.8
97.1
57
198.8
22.8
198.8
195.2
170.5
145.8
121.2
96.5
187.8
25.1
187.8
183.9
159.2
134.4
109.7
85.0
7000
77
248.3
23.6
140.9
104.7
77.1
-
-
-
227.3
25.9
139.8
99.1
71.4
-
-
-
72
226.1
23.2
169.8
142.2
114.6
87.0
-
-
208.1
25.5
164.3
136.6
108.9
81.3
-
-
67
204.0
22.9
198.7
179.8
152.2
124.6
97.0
-
188.9
25.2
188.8
174.1
146.4
118.7
91.1
-
62
193.4
22.6
193.4
193.4
191.3
163.7
136.1
108.5
180.2
24.8
180.2
180.2
180.2
158.3
130.1
102.4
57
201.9
22.8
201.9
200.1
184.1
156.5
128.9
101.3
190.6
25.1
190.6
188.6
172.4
145.8
117.0
89.3
8000
77
252.1
23.7
161.2
113.3
82.7
-
-
-
230.6
26.0
164.3
107.6
76.9
-
-
-
72
229.6
23.3
184.1
153.6
123.1
92.5
-
-
211.1
25.6
178.6
148.0
117.3
86.7
-
-
67
207.1
22.9
207.1
194.0
163.4
132.9
102.4
-
191.7
25.2
191.7
188.3
157.7
127.0
96.4
-
62
196.4
22.6
196.4
196.4
205.4
174.9
144.4
113.8
182.8
24.9
182.8
182.8
182.8
170.1
138.4
107.8
57
205.1
22.9
205.1
205.1
197.7
167.2
136.6
106.1
193.3
25.2
193.3
193.3
185.7
157.2
124.4
93.7
9000
72
233.2
23.5
193.9
160.2
126.5
92.8
-
-
214.2
25.8
188.4
154.6
120.8
87.0
-
-
67
210.3
23.2
210.3
201.6
168.0
134.3
100.6
-
194.5
25.5
194.5
194.5
162.4
128.6
94.8
-
62
199.4
22.8
199.4
199.4
203.9
170.3
136.6
102.9
185.4
25.1
185.4
185.4
185.4
161.6
127.3
93.5
57
208.3
23.1
208.3
208.3
203.2
169.5
135.9
102.2
196.1
25.4
196.1
196.1
191.3
158.5
123.7
89.9
10000
72
236.7
23.8
203.6
166.8
129.9
93.1
-
-
217.2
26.1
198.2
161.3
124.3
87.4
-
-
67
213.5
23.4
213.5
209.3
172.5
135.7
98.9
-
197.2
25.7
197.2
197.2
167.1
130.2
93.2
-
62
202.5
23.1
202.5
202.5
202.5
165.6
128.8
92.0
188.1
25.4
188.1
188.1
188.1
153.1
116.1
79.2
57
211.4
23.4
211.4
211.4
208.7
171.9
135.1
98.3
198.9
25.7
198.9
198.9
196.8
159.9
123.0
86.0
1
These capacities are gross ratings. For net capacity, deduct supply air blower motor, MBh. Example: Refer to the appropriate Blower
Performance Table for the BHP of the supply air blower motor, MBh = 3.415 x kW and kW = BHP x 0.746
nameplate rated motor
efficiency.
2
These ratings include the condenser fan motors and the compressor motors but not the supply air blower motor.
J20PD/J20ND
(Continued)
Air on
Evaporator Coil
Temperature of Air on Condenser Coil
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
CFM
WB
(°F)
Return Dry Bulb (°F)
Return Dry Bulb (°F)
90
85
80
75
70
65
90
85
80
75
70
65
Summary of Contents for Duct R-410A
Page 81: ...505429 JTG L 0512 Johnson Controls Unitary Products 81 Typical J10 12YC Wiring Diagram ...
Page 82: ...505429 JTG L 0512 82 Johnson Controls Unitary Products Typical J10 12YD Wiring Diagram ...
Page 83: ...505429 JTG L 0512 Johnson Controls Unitary Products 83 Typical J15YC Wiring Diagram ...
Page 84: ...505429 JTG L 0512 84 Johnson Controls Unitary Products Typical J20YC Wiring Diagram ...
Page 85: ...505429 JTG L 0512 Johnson Controls Unitary Products 85 Typical J25YC Wiring Diagram ...
Page 86: ...505429 JTG L 0512 86 Johnson Controls Unitary Products Typical J15 20YD Wiring Diagram ...
Page 88: ...505429 JTG L 0512 88 Johnson Controls Unitary Products Typical J10PC Wiring Diagram ...
Page 89: ...505429 JTG L 0512 Johnson Controls Unitary Products 89 Typical J15 20PC Wiring Diagram ...
Page 90: ...505429 JTG L 0512 90 Johnson Controls Unitary Products Typical J15 20PD Wiring Diagram ...
Page 95: ...505429 JTG L 0512 Johnson Controls Unitary Products 95 Typical J25NC Wiring Diagram ...